CHICAGO, IL —
OSHA Inspection: NATION'S BEST - ILLINOIS, LLC DBA CRAFTY BEAVER HOME CENTER HOLDINGS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NATION'S BEST - ILLINOIS, LLC DBA CRAFTY BEAVER HOME CENTER HOLDINGS LLC in 4306 NORTH CENTRAL AVENUE, CHICAGO, IL 60634 (NAICS 423310). OSHA activity number 347273369.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 4306 NORTH CENTRAL AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60634
- Mailing
- 5151 BELT LINE ROAD, DALLAS, TX 75254
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 C01
- Issued
- Mar 12, 2024
- Abate by
- Mar 29, 2024
- Penalty
- Initial $16,131 · Current $8,500 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw was not guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be positive, reliable, and in true alignment with the saw; and the mounting shall be adequate in strength to resist any reasonable side thrust or other force tending to throw it out of line: a) Saw Area- On or about February 12, 2024, the employer did not provide a hood guard over the saw blade table saws, such as on the Delta Table Saw, that completely enclosed the portion of the saw blade above the table, that was of adequate strength to resist blows and strains during operation, that automatically adjusts itself to the thickness of the material being cut and that is mounted to insure reliable and true alignment with the saw. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $8500
- — Z (S) $16131
1910.213 C03
- Issued
- Mar 12, 2024
- Abate by
- Mar 29, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut: a) Saw Area- On or about February 12, 2024, the employer did not ensure functional non kickback fingers were provided table saws, such as on the Delta Table Saw that could provide adequate holding power for all wood that was ripped and cut by the saw to prevent kickback towards the operator. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 G02
- Issued
- Mar 12, 2024
- Abate by
- Mar 29, 2024
- Penalty
- Initial $9,218 · Current $6,500 Reduced
General-duty citation text
29 CFR 1910.213(g)(2): Swing cutoff saw(s) were not provided with an effective device to return the saw automatically to the back of the table when released at any point of its travel: a) Saw Area- On or about February 12, 2024, the employer did not ensure cutoff saws, such as the Delta Cutoff Saw, would automatically return to the home position when released. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $6500
- — Z (S) $9218
More inspections in this industry (NAICS 423310)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347273369.