Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REGENCY PLASTICS-UBLY, INC-TX

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REGENCY PLASTICS-UBLY, INC-TX in 1101 BURGUNDY DR., EL PASO, TX 79907 (NAICS 326121). OSHA activity number 347283210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Regency Plastics-Ubly, Inc-Tx — free Get an email when a new federal OSHA severe-injury report for Regency Plastics-Ubly, Inc-Tx is published. One employer, no account, unsubscribe in one click.
Site address
1101 BURGUNDY DR.
City
EL PASO
State
TX
ZIP
79907
Mailing
1101 BURGUNDY DR., EL PASO, TX 79907
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326121
Employees
1324
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 13, 2024
Penalty
Initial $11,524 · Current $7,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about February 15, 2024, Production Line #13; the guard for the drive shaft to Extruder #13 was broken and or missing. This condition exposed employees to struck-by and caught-between hazards.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $11524

1910.305 G02 III

Serious Gravity 1 2 instances 2 exposed
Issued
Mar 13, 2024
Penalty
Initial $6,913 · Current $4,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   On or about February 15, 2024, employees were exposed to electrical shock and burn hazards in the following instances:  a) Production Line #13: The Melt Pump Control Box to the extruder had a strain relief that was broken and electrical wires were exposed.  b) Production Line #4: The control panel to Grinder #34 had a strain relief that was broken and wires were exposed.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6913

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 13, 2024
Penalty
Initial $1,294 · Current $1,000 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Production Line #1: On or about February 15, 2024, employees were exposed to electrical shock hazards in that a relocatable power tap was permanently secured to Rousselle Press #27 and not used or installed in accordance with the instruction included in the listing and labeling.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1294

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 13, 2024
Abate by
Apr 1, 2024
Penalty
Initial $1,294 · Current $1,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about February 15, 2024, near Production Line #4; an electrical panel cover was not securely fastened in place. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1294

View Regency Plastics-Ubly, Inc-Tx's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347283210.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.