QUITMAN, TX —
OSHA Inspection: PCI ENTERPRISES INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PCI ENTERPRISES INC in 4300 FM 2225, QUITMAN, TX 75783 (NAICS 337212). OSHA activity number 347287047.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCI ENTERPRISES INC
- Site address
- 4300 FM 2225
- City
- QUITMAN
- State
- TX
- ZIP
- 75783
- Mailing
- 6765 HORIZON RD, HEATH, TX 75032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 22
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 D01
- Issued
- Jun 5, 2024
- Abate by
- Jul 2, 2024
- Penalty
- Initial $13,828 · Current $8,266 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition: (a) On or about February 16, 2024, and times prior to, where extension cords outside the door of the paint booth area, extends across the floor, exposing employees to a trip and fall hazard.
Recent events (2)
- — I (S) $8266
- — Z (S) $13828
1910.37 B02
- Issued
- Jun 5, 2024
- Abate by
- Jul 2, 2024
- Penalty
- Initial $16,131 · Current $9,578 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." On or about February 16, 2024, and times prior to, where the employer did not have an exit sign at the exit door. Employees were exposed to a fire hazard. (a) No exit sign at the door, at the front hallway, that leads to the foyer. (b) No exit sign at the main front office door that leads to outside. (c) No exit sign at the machine CNC production area that leads to outside. (d) No exit signs at two (2) back doors that leads to outside.
Recent events (2)
- — I (S) $9578
- — Z (S) $16131
1910.178 L06
- Issued
- Jun 5, 2024
- Abate by
- Jul 2, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required: (a) On or about February 16, 2024, and times prior to, employees operate powered industrial trucks throughout the facility without being trained, evaluated and certified.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
1910.303 E01 II
- Issued
- Jun 5, 2024
- Abate by
- Jul 2, 2024
- Penalty
- Initial $16,131 · Current $9,578 Reduced
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary had not been placed on equipment being used: (a) This violation occurred on or about February 16, 2024, and times prior thereto, in the Assembly area where electrical control panel boxes did not have markings.
Recent events (2)
- — I (S) $9578
- — Z (S) $16131
1910.305 D02
- Issued
- Jun 5, 2024
- Abate by
- Jul 2, 2024
- Penalty
- Initial $16,131 · Current $9,578 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards mounted in cabinets, cutout boxes, or enclosures designed for the purpose and were not dead front. However, panelboards other than the dead front externally operable type are permitted where accessible only to qualified persons: On or about February 16, 2024, and times prior to, the employer did not ensure the electrical panel boxes had a dead front enclosure to prevent electrical hazards. (a) Level 1, Small electrical panel box, 220 volts that powers the refrigerator and is connected to a main 480 volts electrical panel box. (b) Level 2, Main electrical panel box, 480 volts that powers all machinery and offices.
Recent events (2)
- — I (S) $9578
- — Z (S) $16131
1910.145 F03
- Issued
- Jun 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(f)(3): Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily: On or about February 16, 2024, and times prior to, where the employer did not have the gas lines marked or tag for identification to prevent potentially hazardous conditions: (a) Gas line valve near the side entrance, exiting the rolling door, not properly marked. (b) Level 1, gas line valve with string attached located at the ceiling
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PCI Enterprises INC
View PCI Enterprises INC's full OSHA safety record →
More inspections in this industry (NAICS 337212)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347287047.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.