OSHA Inspection: DANIEL PASILLAS MARTINEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DANIEL PASILLAS MARTINEZ in 10833 SPANISH HILLS DRIVE, FORT WORTH, TX 76126 (NAICS 238350). OSHA activity number 347289290.

Watch Daniel Pasillas Martinez — free Get an email when a new federal OSHA severe-injury report for Daniel Pasillas Martinez is published. One employer, no account, unsubscribe in one click.
Site address
10833 SPANISH HILLS DRIVE
City
FORT WORTH
State
TX
ZIP
76126
Mailing
3425 CHILDRESS STREET, FORT WORTH, TX 76119
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 G01 VII

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2351.00 · Current $1646.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On February 16, 2024, and times prior thereto, employees work from a pole scaffold without fall protection systems while installing cornice material on the exterior of a residential home. The employees were exposed to fall hazards of approximately 15 feet to the ground below.
Recent events (2)
  • — I (O) $1645.7
  • — Z (S) $2351

1926.452 A04

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2074.00 · Current $1452.00 Reduced
29 CFR  1926.452(a)(4): Diagonal bracing in both directions were not installed across the entire outside face of all double- and single-pole scaffolds.   On February 16, 2024, and times prior thereto, employees working from a pole scaffold without cross bracing installed were exposed to a collapse and falling approximately 15 feet to the ground below.
Recent events (2)
  • — I (O) $1451.8
  • — Z (S) $2074

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $330.00 · Current $231.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.   On February 16, 2024, and times prior thereto, employees engaged in cornice work utilized an extension cord with missing ground pin exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $231
  • — Z (O) $330

1926.451 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $388.00 · Current $272.00 Reduced
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide.   On February 16, 2024, and times prior thereto, employees engaged in cornice work on a residential home from single pole scaffold, work from a platform not 18 inches wide. The employees were exposed to potential fall hazard of approximately 15 feet to the ground below.
Recent events (2)
  • — I (O) $271.6
  • — Z (O) $388