Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEVIN NUNEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEVIN NUNEZ in 3914 LA CONTENTA LANE, HUTTO, TX 78634 (NAICS 238170). OSHA activity number 347290264.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kevin Nunez — free Get an email when a new federal OSHA severe-injury report for Kevin Nunez is published. One employer, no account, unsubscribe in one click.
Establishment
KEVIN NUNEZ
Site address
3914 LA CONTENTA LANE
City
HUTTO
State
TX
ZIP
78634
Mailing
109 JASMIN WAY, HUTTO, TX 78634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $2,074 · Current $1,244 Reduced
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  On or about February 6, 2024, employees were performing exterior work to a new home under construction without receiving training from the employer, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

1926.454 A

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.454(a):The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures to control or minimize those hazards.  On or about February 6, 2024, on the south side of the home; employees were performing work from a pump jack without training to recognize those hazards, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 17, 2024
Penalty
Initial $1,763 · Current $1,058 Reduced
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   On or about February 6, 2024, an employee was using an extension cord with damaged strain relief to power a circular saw, exposing the employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $1057.8
  • — Z (S) $1763

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 17, 2024
Penalty
Initial $3,526 · Current $2,116 Reduced
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   On or about February 6, 2024, employees were installing exterior Thermoply/sheathing on a residential home working from a pumpjack at heights above approximately 10 feet without fall protection; exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $2115.6
  • — Z (S) $3526

1926.452 J02

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 17, 2024
Penalty
Initial $2,074 · Current $1,244 Reduced
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   On or about February 6, 2024, employees were installing exterior Thermoply/sheathing on a residential home from a pump jack scaffold that was not erected with rigid triangular bracing, exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

1926.451 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 17, 2024
Abate by
Aug 12, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  On or about February 6, 2024, employees were installing exterior sheathing on a residential home from a pump jack scaffold that was erected without base plates or mud sills, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Kevin Nunez's full OSHA safety record →