OSHA Inspection: FUYAO GLASS ILLINOIS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FUYAO GLASS ILLINOIS, INC. in 2768 E ELWIN RD, DECATUR, IL 62521 (NAICS 327212). OSHA activity number 347290413.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fuyao Glass Illinois, INC. — free Get an email when a new federal OSHA severe-injury report for Fuyao Glass Illinois, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2768 E ELWIN RD
City
DECATUR
State
IL
ZIP
62521
Mailing
2768 E ELWIN RD, DECATUR, IL 62521
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327212
Employees
415
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Deleted Serious Gravity 5 1 instance 24 exposed
Issued
Aug 1, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about February 20, 2024, employees were exposed to corrosive chemicals in the battery maintenance area and the employer failed to ensure the eyewash station was suitable for immediate emergency use. The eyewash was impeded by the wash bay walls, lifting fixture and hoses.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.303 G01 I A

Other-than-serious Gravity 1 1 instance 24 exposed
Issued
Aug 1, 2024
Penalty
Initial $6,913 · Current $1,500 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  On or about February 20, 2024, the employer failed to ensure the area of 3 feet around the transformer was kept clear on the exterior of the quality lab.  The area around the transformer was blocked by trash, cleaning materials, and snow removal items.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $6913

1910.303 G02 I

Deleted Other-than-serious 1 instance 415 exposed
Issued
Aug 1, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  On or about February 20, 2024, the employer failed to ensure live parts operating at 50 volts or more were guarded against accidental contact by utilizing an outlet plate cover. The outlet cover located at stanchion D54 was missing the outlet plate cover exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 H02 III A

Deleted Other-than-serious 1 instance 24 exposed
Issued
Aug 1, 2024
Abate by
Sep 9, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(h)(2)(iii)(A): The installations shall be made with metal-enclosed equipment or shall be enclosed in a vault or in an area to which access is controlled by a lock:   On or before February 20, 2024, employees were exposed to electrical shock hazards in that the electrical cabinets on the C11-1 Powdering Machine had broken or missing locks permitting access to live parts to operators and unauthorized employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fuyao Glass Illinois, INC.'s full OSHA safety record →