Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ESPITIA'S CABINET & DOOR MAKERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ESPITIA'S CABINET & DOOR MAKERS, INC. in 8529 RANNIE ROAD, HOUSTON, TX 77080 (NAICS 337110). OSHA activity number 347299166.

Watch Espitia'S Cabinet & Door Makers, INC. — free Get an email when a new federal OSHA severe-injury report for Espitia'S Cabinet & Door Makers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8529 RANNIE ROAD
City
HOUSTON
State
TX
ZIP
77080
Mailing
8529 RANNIE ROAD, HOUSTON, TX 77080
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
29
Ownership type
A

15 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 2 instances 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR  1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  1. On or about February 22, 2024, at the main warehouse employees were exposed to slip, trip and combustible dust hazards as there was caked on sawdust on the walls and multiple small piles of sawdust on electrical equipment and on and around the floor of machines which were not cleaned adequately.   2. On or about February 22, 2024, at warehouse #2 employees were exposed to slip, trip and combustible dust hazards as there was a pile of saw dust on an electrical outlet which was not adequately cleaned up.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1910.242 B

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $6,453 · Current $3,872 Reduced
29 CFR 1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about February 22, 2024, at the main warehouse employees were exposed to struck-by hazards as compressed blow down air used at machines was not reduced to less than 30 p.s.i.
Recent events (2)
  • — I (S) $3871.8
  • — Z (S) $6453

1910.213 C01

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR 1910.213(c)(1):Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  On or about February 22, 2024, at the main warehouse where an employee was exposed to lacerations and amputations as he was using a dual six inch table saw that did not have a protective hood in place.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1910.213 C02

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2):Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  On or about February 22, 2024, at the main warehouse an employee was exposed to lacerations and amputations as there was a six inch dual table saw that was in use and did not have a spreader in place while employees rip and cut wood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3):Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  On or about February 22, 2024, at the main warehouse an employee was exposed to lacerations and amputations as there was a six inch dual table saw that was in use and did not have an anti-kick back device in place while employee rip and cut wood.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:(a)   1. On or about February 22, 2024, at both warehouses employees were exposed to electrical hazards where electrical power strips were improperly used and mounted.  2. On or about February 22, 2024, at both warehouses employees were exposed to electrical hazards where electrical extension cords were used on a permanent basis.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1910.303 B07 IV

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(7)(iv):There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating.  On or about February 22, 2024, at warehouse #2 employees were exposed to an electrical hazard as there was a broken light switch at the front door.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  1. On or about February 22, 2024, at the main warehouse employees were exposed to an electrical hazards while using power strip whose strain relief had been damaged.  2. On or about February 22, 2024, at warehouse #2 employees were exposed to electrical hazards while using a circular saw and an extension cord whose strain relief was damaged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.304 F01 IV

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR  1910.304(f)(1)(iv):Overcurrent devices for circuits rated 600 volts, nominal, or less, were located where they were exposed to physical damage:  On or about February 22, 2024, at warehouse #2 employees were exposed to electrical hazards with electrical equipment such as knife switches that did not have sufficient access around them.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1910.304 G05

Serious Gravity 5 1 instance 29 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.304(g)(5):The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  On or about February 22, 2024, at the main warehouse employees were exposed to an electrical hazard as there was a power cord to a power strip that did not have a ground prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $6,453 · Current $3,872 Reduced
29 CFR 1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   On or about February 19, 2024, at warehouse #2 the employer did not have a hazard communication program while using chemicals such as paint thinner, metal finish, propane, compressed oxygen and acetylene.
Recent events (2)
  • — I (S) $3871.8
  • — Z (S) $6453

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about February 19, 2024, at warehouse #2 employees were not trained while using chemicals such as paint thinner, metal finish, propane, compressed oxygen and acetylene.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G01

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $6,453 · Current $3,872 Reduced
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use.  On or about January 11, 2024, at warehouse #2 employees were exposed to upper respiratory and explosive hazards as the employer did not have safety data sheets for chemicals such as paint thinner, metal finish, propane, compressed oxygen and acetylene.
Recent events (2)
  • — I (S) $3871.8
  • — Z (S) $6453

1910.37 A03

Other-than-serious 1 instance 4 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed:  On or about February 22, 2024, at warehouse #2 there was an exit door blocked by shelving and other equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 B02

Other-than-serious 1 instance 4 exposed
Issued
May 10, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit":  On or about February 22, 2024, at warehouse #2 there was an exit sign that was broken and not utilized.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347299166.