OSHA Inspection: HB&G BUILDING PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HB&G BUILDING PRODUCTS, INC. in 1015 BRUNDIDGE BLVD., TROY, AL 36081 (NAICS 326199). OSHA activity number 347300352.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HB&G Building Products, INC. — free Get an email when a new federal OSHA severe-injury report for HB&G Building Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1015 BRUNDIDGE BLVD.
City
TROY
State
AL
ZIP
36081
Mailing
1015 BRUNDIDGE BLVD., TROY, AL 36081
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
200
Ownership type
A

1 citation on file for this inspection.

1910.305 B01 II

Other-than-serious 2 instances 30 exposed
Issued
Apr 25, 2024
Abate by
May 7, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a) Maintenance Department (Electronic Panel Box - Front Area): On or about February 20, 2024, and times prior, the employer failed to effectively close unused knockout hole(s) and opening(s) in a Class-CTL Enclosed Panel Box (MSPP1).  b) Maintenance Department (Electronic Panel Box - Shop Area): On or about February 20, 2024, and times prior, the employer failed to effectively close unused knockout hole(s) and opening(s) in a Siemens Indoor Panel Box (MSPP2).  c) Chemical Storage (Electronic Panel Box Pultrusion Line Door - Middle): On or about February 20, 2024, and times prior, the employer failed to effectively close unused knockout hole(s) and opening(s) in a GE PowerMark Plus Load Center TL42BC1.  d) Pultrusion Line (Electronic Panel Box - Front Door Area - Middle): On or about February 20, 2024, and times prior, the employer failed to effectively close an conduit opening in a GE A-Series II Panelboard AF49S.
Recent events (1)
  • — Z (O) $0