OSHA Inspection: KEVLON FOODS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KEVLON FOODS INC. in 166 EAST 4TH STREET, DUNKIRK, NY 14048 (NAICS 445110). OSHA activity number 347305641.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kevlon Foods INC. — free Get an email when a new federal OSHA severe-injury report for Kevlon Foods INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KEVLON FOODS INC.
Site address
166 EAST 4TH STREET
City
DUNKIRK
State
NY
ZIP
14048
Mailing
166 EAST 4TH STREET, DUNKIRK, NY 14048
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
19
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 14, 2024
Abate by
Apr 15, 2024
Penalty
Initial $6,452 · Current $3,226 Reduced
29 CFR 1910.147(c)(1): The employer did not establish an energy control program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated and rendered inoperable.  a) On or about  02/22/2024, in the Meat Room; an energy control program was not established that consists of specific energy control procedures, authorized employee training, and periodic inspections to ensure employees perform energy control procedures before servicing or doing maintenance such as but not limited to, unjamming and changing the blade on the Hobart vertical band saw Model #5801 - Serial #27-134-200.  Employees were exposed to amputation hazards.   ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $3226
  • — Z (S) $6452

1910.178 L06

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Mar 14, 2024
Penalty
Initial $2,350 · Current $1,175 Reduced
1910.178(l)(6)  Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) On or about 02/28/24, in the warehouse area;  employees were exposed to struck by hazards when the employer did not ensure operators were trained and evaluated in the safe operations of electrical pallet jack (Toyota Electric Truck Model # 8HBW23, Serial # 8HBW23-34569).  Electric pallet jacks are used to bring products from the warehouse area to the store floor.  NO ABATEMENT CERTIFICATION REQUIRED