NAPERVILLE, IL —
OSHA Inspection: SHERMAN PLASTICS CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SHERMAN PLASTICS CORP. in 1650 SHORE RD, NAPERVILLE, IL 60563 (NAICS 326199). OSHA activity number 347306235.
Where did this inspection happen?
- Establishment
- SHERMAN PLASTICS CORP.
- Site address
- 1650 SHORE RD
- City
- NAPERVILLE
- State
- IL
- ZIP
- 60563
- Mailing
- 1650 SHORE RD, NAPERVILLE, IL 60563
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 11, 2024
- Abate by
- May 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. (a): On or about December 8, 2023, the employer did not have a documented energy control procedure for service and maintenance activities on the compounding line #1. (b): On or about February 27, 2024, the employer did not have a documented energy control procedure for service and maintenance activities on the compounding line #1. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 II
- Issued
- Apr 11, 2024
- Abate by
- May 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. (a): On or about December 8, 2023, the employer did not document periodic inspections of the energy control procedure for service and maintenance activities on the compounding line #1. (b): On or about February 27, 2024, the employer did not document periodic inspections of the energy control procedure for service and maintenance activities on the compounding line #1. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Sherman Plastics Corp.
View Sherman Plastics Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in IL
Source