WILMINGTON, MA —
OSHA Inspection: M & JARA KING CONSTRUCTION CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of M & JARA KING CONSTRUCTION CORPORATION in 7 HEATHER DRIVE, WILMINGTON, MA 01887 (NAICS 238170). OSHA activity number 347306532.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & JARA KING CONSTRUCTION CORPORATION
- Site address
- 7 HEATHER DRIVE
- City
- WILMINGTON
- State
- MA
- ZIP
- 01887
- Mailing
- 53 LEXINGTON ST APT 3, LAWRENCE, MA 01841
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G02
- Issued
- May 1, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.451(g)(2): The employer did not have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Location: Job Site; On or about 02/27/24, the employer failed to determine by way of a competent person, the feasibility and safety of providing fall protection for an employee who was 14-feet above the ground on a residential roof, removing the triangular bracing of a pump jack scaffold from the roof's surface.
Recent events (1)
- — Z (S) $4839
1926.501 B13
- Issued
- May 1, 2024
- Penalty
- Initial $4,839 · Current $4,839
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). Location: Job site; On or about 02/27/24, an employee was allowed to access the roof of a residence that was 14-feet above the ground below to remove pump jack triangular bracing from the roof of the residence. The employee was allowed to carry out this job task without being protected from falling by any form of fall protection equipment.