CLEARWATER, FL —
OSHA Inspection: INSTRUMENT TRANSFORMERS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INSTRUMENT TRANSFORMERS, LLC in 1907 CALUMET STREET, CLEARWATER, FL 33765 (NAICS 335929). OSHA activity number 347311714.
Where did this inspection happen?
- Establishment
- INSTRUMENT TRANSFORMERS, LLC
- Site address
- 1907 CALUMET STREET
- City
- CLEARWATER
- State
- FL
- ZIP
- 33765
- Mailing
- 1907 CALUMET STREET, CLEARWATER, FL 33765
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335929
- Employees
- 650
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $11524.00 · Current $7491.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) At the 1907 Calumet Street Clearwater, Florida: On or about 2/21/2024; employees were exposed to crushed-by and struck-by hazards, in that, the employer's machine specific Lock Out Tag Out procedure for the Rudel punch press did not include the identification of the kinetic energy as an energy form, the sources for kinetic energy, the purpose, and the specific steps to dissipating stored kinetic energy.
Recent events (2)
- — I (S) $7490.6
- — Z (S) $11524
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the 1907 Calumet Street Clearwater, Florida: On or about 2/21/2024; employees were exposed to crushed-by and struck-by hazards, in that, the employer did not conduct an annual inspection of the energy control procedure for the Rudel punch press.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 D02
- Issued
- Abate by
- Penalty
- Initial $11524.00 · Current $7491.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): An orderly shutdown of machine or equipment was not utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage: (a) At the 1907 Calumet Street Clearwater, Florida: On or about 2/21/2024; the Rudel punch press had not been shutdown and locked prior performing service and maintenance, exposing employees to crushed-by and struck-by hazards.
Recent events (2)
- — I (O) $7490.6
- — Z (S) $11524
More inspections at INSTRUMENT TRANSFORMERS, LLC
CLEARWATER, FL—2023-05-09 00:00:00
INSTRUMENT TRANSFORMERS, LLC
CLEARWATER, FL—2017-10-13 00:00:00
INSTRUMENT TRANSFORMERS, LLC
CLEARWATER, FL—2016-04-19 00:00:00
INSTRUMENT TRANSFORMERS, LLC.
CLEARWATER, FL—2016-03-31 00:00:00
INSTRUMENT TRANSFORMERS, LLC
CLEARWATER, FL—2016-02-19 00:00:00
INSTRUMENT TRANSFORMERS, LLC
View INSTRUMENT TRANSFORMERS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 335929)
JAMESTOWN, CA—2026-06-09 00:00:00
ENGIE NORTH AMERICA INC.
EAST GRANBY, CT—2026-05-14 00:00:00
MARMON INDUSTRIAL ENERGY & INFRASTRUCTURE
LINCOLN, RI—2026-04-20 00:00:00
PRYSMIAN CABLES AND SYSTEMS USA, LLC
BOURBONNAIS, IL—2026-04-03 00:00:00
MRO, INC.
JONESBORO, LA—2026-01-29 00:00:00
ENTERGY LOUISIANA, LLC
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347311714.