OSHA Inspection: JOAQUIN ENTERPRISES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of JOAQUIN ENTERPRISES, LLC in 6900 ELM DRIVE, COMMERCE CITY, CO 80022 (NAICS 332311). OSHA activity number 347315939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Joaquin Enterprises, LLC — free Get an email when a new federal OSHA severe-injury report for Joaquin Enterprises, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6900 ELM DRIVE
City
COMMERCE CITY
State
CO
ZIP
80022
Mailing
6900 ELM DRIVE, COMMERCE CITY, CO 80022
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.134 E01

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Jul 23, 2024
Abate by
Aug 26, 2024
Penalty
Initial $4,839 · Current $4,250 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) JoaQuin Enterprises, LLC: On or about February 23, 2024, and at times prior, employees were exposed to respiratory hazards while wearing tight-fitting respirators while performing painting and welding operations.  The employer did not ensure that each employee wearing a tight-fitting respirator was medically evaluated to wear a tight-fitting respirator prior to use.
Recent events (2)
  • — I (O) $4250
  • — Z (S) $4839

1910.134 F02

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jul 23, 2024
Abate by
Aug 26, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  a) JoaQuin Enterprises, LLC: On or about February 23, 2024, and at times prior, employees were required to wear tight-fitting respirators while performing painting and welding operations. The employer did not ensure that each employee required to wear a tight-fitting respirator was fit tested prior to initial use and annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jul 23, 2024
Abate by
Aug 26, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  a) JoaQuin Enterprises, LLC: On or about February 23, 2024, and at times prior, employees were required to wear tight-fitting respirators while performing painting and welding operations. Respirators were being stored in non-airtight toolboxes that were contaminated with hazards such as but not limited to dust particles from painting and welding operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A02 XV

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Jul 23, 2024
Abate by
Aug 15, 2024
Penalty
Initial $9,680 · Current $4,250 Reduced
29 CFR 1910.252(a)(2)(xv): Cutting or welding was permitted not only in areas that were or had been made fire safe:  a) JoaQuin Enterprises, LLC: On or about February 23, 2024, and at times prior, employees were exposed to fire hazards while conducting welding operations. The designated welding stations did not have guards in place to confine the heat, sparks, and slag produced.  The employer did not ensure employees were protected from fire hazards while conducting welding operations in designated welding stations.
Recent events (2)
  • — I (O) $4250
  • — Z (S) $9680

1910.252 B02 III

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 23, 2024
Abate by
Aug 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used:  a) JoaQuin Enterprises, LLC: On or about February 23, 2024, and at times prior, employees were exposed to UV light produced from welding operations. The employer did not ensure affected employees were provided with the appropriate eye protection or that welding operations were appropriately guarded by the use of screens or shields.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Joaquin Enterprises, LLC's full OSHA safety record →