BROOKLYN, NY —
OSHA Inspection: SINYC AV INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SINYC AV INC. in 135 11TH STREET, BROOKLYN, NY 11215 (NAICS 493110). OSHA activity number 347321895.
Where did this inspection happen?
- Establishment
- SINYC AV INC.
- Site address
- 135 11TH STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11215
- Mailing
- 135 11TH STREET, BROOKLYN, NY 11215
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $4610.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. Site: 135 11th Street in Brooklyn, NY. On or about 3/5/2024, exit routes in the work site were not free and unobstructed as required. a) Exit was blocked by parked and covered motorcycles. b) Another exit was blocked by collection bin and was locked.
Recent events (1)
- — Z (S) $4610
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $4610.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Site: 135 11th Street in Brooklyn, NY. a) On or about 3/5/2024, workers used a power distribution device to power lighting and equipment on site. The flexible power cord for the device was not provided strain relief as required and was damaged.
Recent events (1)
- — Z (S) $4610
More inspections at SINYC AV INC.
BROOKLYN, NY—2024-10-17 00:00:00
SINYC AV INC.
BROOKLYN, NY—2024-10-17 00:00:00
SINYC AV INC.
BROOKLYN, NY—2024-03-05 00:00:00
SINYC AV INC.
View SINYC AV INC.'s full OSHA safety record →
More inspections in this industry (NAICS 493110)
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
BLACK MOUNTAIN, NC—2026-07-07
161500 - INGLES MARKETS, INCORPORATED - DISTRIBUTION CENTER
FRANKLIN, KY—2026-07-07
69287 - TRACTOR SUPPLY COMPANY
PARKERSBURG, WV—2026-07-07
PEOPLES CARTAGE INC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347321895.