PEWAUKEE, WI —
OSHA Inspection: PROHEALTH WEST WOOD HEALTH & FITNESS CENTER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PROHEALTH WEST WOOD HEALTH & FITNESS CENTER in 2900 GOLF ROAD, PEWAUKEE, WI 53072 (NAICS 713940). OSHA activity number 347322109.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROHEALTH WEST WOOD HEALTH & FITNESS CENTER
- Site address
- 2900 GOLF ROAD
- City
- PEWAUKEE
- State
- WI
- ZIP
- 53072
- Mailing
- 2900 GOLF ROAD, PEWAUKEE, WI 53072
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713940
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Jul 26, 2024
- Abate by
- Aug 20, 2024
- Penalty
- Initial $11,292 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) On or about March 5, 2024, the employer had not established an energy control program consisting of machine specific energy control procedures, employee training and periodic inspections, to ensure employees are protected during servicing and maintenance activities.
Recent events (3)
- — F (S) $0
- — C (S) $11292
- — Z (S) $11292
1910.147 C04 I
- Issued
- Jul 26, 2024
- Abate by
- Aug 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about March 5, 2024, the employer had not developed, documented and utilized machine specific procedures for, but not limited to the Mr. Steam Commercial Steam Bath Generator Model No. CU1000A/Serial No. AXD-622A-016, that employees or outside contractors perform lockout/tagout on for maintenance and cleaning activities.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jul 26, 2024
- Abate by
- Aug 20, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) On or about March 5, 2024, the employer had not trained the employees on the hazardous energy control program and how to recognize lockout/tagout procedures and that procedures are actively implemented.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 F02 I
- Issued
- Jul 26, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $0 · Current $3,388
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures: (a) On or about March 5, 2024, the host employer, ProHealth West Wood Health & Fitness Center, did not inform or discuss with the contractor employer performing servicing and maintenance on the Mr. Steam Commercial Steam Bath Generator (Model No. CU1000A/Serial No. AXD-622A-016) each other's respective lockout or tagout program and procedures prior to conducting servicing and maintenance work on the Mr. Steam Commercial bath generator.
Recent events (3)
- — F (O) $3387.6
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 713940)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347322109.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.