BROOKLYN, NY —
OSHA Inspection: CUBE BUILDERS GROUP NY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUBE BUILDERS GROUP NY INC. in 2285 WEST 6TH STREET, BROOKLYN, NY 11223 (NAICS 238350). OSHA activity number 347324782.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUBE BUILDERS GROUP NY INC.
- Site address
- 2285 WEST 6TH STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11223
- Mailing
- 174 AVE. S 2ND FLOOR, BROOKLYN, NY 11223
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.403 I02 I
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $3,457 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i):Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure that live parts in electrical panelboards were guarded against accidental contact by cabinets or equivalent means; the electrical panelboard on the basement level was not guarded against accidental contact.
Recent events (2)
- — I (S) $2500
- — Z (S) $3457
1926.405 J01 I
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $2,765 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.405(j)(1)(i):Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure that live parts were exposed to employee contact; energized outlets/receptacles used to energize tools, such as a DeWalt DWS782 Miter Saw, were not installed with covers.
Recent events (2)
- — I (S) $2100
- — Z (S) $2765
1926.405 J01 II
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(1)(ii):Fixtures, lampholders, rosettes, or receptacles were not securely supported: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure that receptacles were securely supported; energized electrical outlets/receptacles used to energize tools, such as a DeWalt DWS782 Miter Saw, were not securely supported.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.416 E01
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $2,765 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.416(e)(1):Worn or frayed electric cords or cables were used: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure that worn electrical cords were not used; a worn electrical cord with a damaged outer jacket was used to energize a Hilti TE-16C Rotary Hammer Drill.
Recent events (2)
- — I (S) $1800
- — Z (S) $2765
1926.451 C02 II
- Issued
- Aug 30, 2024
- Penalty
- Initial $4,148 · Current $2,600 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(ii):Unstable objects were used to support scaffolds or platform units: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure unstable objects were not used to support platform units; an employee worked from a unsecured wooden plank supported by three stacked masonry bricks.
Recent events (2)
- — I (S) $2600
- — Z (S) $4148
1926.1052 C01 I
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $2,074 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure stairways having four or more rises were equipped with at least one handrail; the stairway leading to the basement level was not equipped with at least one handrail.
Recent events (2)
- — I (S) $1500
- — Z (S) $2074
1926.1052 C01 II
- Issued
- Aug 30, 2024
- Abate by
- Sep 12, 2024
- Penalty
- Initial $2,074 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: Location: 2285 West 6th Street, Brooklyn, NY 11223 On or about: March 4, 2024 (a) The employer did not ensure stairways having four or more rises were equipped with a stairrail system along each unprotected side; the front entrance stairs leading to inside the building was not equipped with stairrail systems along unprotected sides.
Recent events (2)
- — I (S) $1500
- — Z (S) $2074
More inspections at Cube Builders Group NY INC.
View Cube Builders Group NY INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347324782.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.