Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ISI AUTOMATION INTERNATIONAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ISI AUTOMATION INTERNATIONAL in 900 E. MARKET STREET, SAN ANTONIO, TX 78205 (NAICS 541519). OSHA activity number 347333973.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ISI Automation International — free Get an email when a new federal OSHA severe-injury report for ISI Automation International is published. One employer, no account, unsubscribe in one click.
Site address
900 E. MARKET STREET
City
SAN ANTONIO
State
TX
ZIP
78205
Mailing
8 DOMINION DRIVE SUITE 106, SAN ANTONIO, TX 78257
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541519
Employees
6
Ownership type
A

2 citations on file for this inspection.

1910.23 C13

Serious Gravity 10 2 instances 4 exposed
Issued
May 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(13): The employer did not ensure that ladders are not placed on boxes, barrels, or other unstable bases to obtain additional height:  Northside of the building, On or about March 8, 2024 and times prior thereto, employees were exposed to a fall hazard while operating a scissor lift used an A-Frame ladder for additional height to reach their work area.
Recent events (1)
  • — Z (S) $0

1910.147 C01

Serious Gravity 10 1 instance 6 exposed
Issued
May 23, 2024
Abate by
Jun 13, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  Northside entrance: On or about March 8, 2024, and at times prior thereto, employees were exposed to electrical hazards associated with unexpected startup or release of stored energy while removing light ballasts that were not locked out.
Recent events (1)
  • — Z (S) $0

View ISI Automation International's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347333973.