Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUNCOVIA, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUNCOVIA, LLC in 387 LEEDS JUNCTION ROAD, WALES, ME 04280 (NAICS 221114). OSHA activity number 347337784.

Watch Suncovia, LLC — free Get an email when a new federal OSHA severe-injury report for Suncovia, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUNCOVIA, LLC
Site address
387 LEEDS JUNCTION ROAD
City
WALES
State
ME
ZIP
04280
Mailing
14500 NORTHSIGHT BOULEVARD SUITE 315, SCOTTSDALE, AZ 85260
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221114
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $6452.00 · Current $3000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  387 Leeds Junction Road, Wales, Maine - Three employees were not protected from falling, while installing solar panels 22 to 35 feet above the ground.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6452
  • — Z (S) $6452

1926.503 A01

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4610.00 · Current $0.00 Reduced
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  387 Leeds Junction Road, Wales, Maine - The employer did not ensure that employees received training on fall hazards prior to working on a metal roof approximately 22 to 35 feet high, with a roof pitch of 7/12.
Recent events (3)
  • — F (O) $0
  • — C (S) $4610
  • — Z (S) $4610

1926.1053 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $4610.00 · Current $3000.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  387 Leeds Junction Road, Wales, Maine - Three employees installing solar panels were accessing a roof off of two 30 foot extension ladders, which were only extended 18 inches past the roof edge.
Recent events (3)
  • — F (S) $3000
  • — C (S) $4610
  • — Z (S) $4610

1926.1053 B22

Other-than-serious 9 instances 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause them to lose balance and fall:  387 Leeds Junction Road, Wales, Maine - Employees were carrying 4x5 foot solar panels up a ladder in high wind conditions.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0