On , OSHA opened a planned safety inspection of CONSTRUCTION SOLUTIONS COMPANY, LLC in 110733 RIO VISTA, POCATELLO, ID 83202 (NAICS 238130). OSHA activity number 347339376.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Construction Solutions Company, LLC — free Get an email when a new federal OSHA severe-injury report for Construction Solutions Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
110733 RIO VISTA
City
POCATELLO
State
ID
ZIP
83202
Mailing
2856 RIDGECREST DRIVE, IDAHO FALLS, ID 83401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 3 instances 2 exposed
Issued
May 24, 2024
Abate by
Jun 13, 2024
Penalty
Initial $4,936 · Current $4,936
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program that provided for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employer;   a) On March 12, 2024, and times prior the employer did not effectively maintain the site inspection system to identify and correct hazards to which their employees were exposed. Hazards included employees not using fall protection, employees using unserviceable fall protection components and employees using non-compatible fall protection components.   b) On March 12, 2024, and times prior the employer did not effectively maintain the site inspection system to identify and correct hazards to which their employees were exposed.  Employees used pneumatic powered hand tools without proper eye protection.   c) On March 12, 2024, and times prior the employer did not effectively maintain the site inspection system to identify and correct hazards to which their employees were exposed.  An energized flexible cord used for temporary power had damaged insulation and exposed energized conductors.   Note) Certification of corrective action is required for these items.
Recent events (1)
  • — Z (S) $4936

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 24, 2024
Abate by
Jun 6, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) On March 12, 2024, and times prior employees were exposed to a 12-foot fall hazard to the ground below while performing framing activities on a flat roof deck without their fall protection attached properly to an anchor point or not at all.    Note) Certification of corrective action is required for this item.
Recent events (1)
  • — Z (S) $0

1926.502 D21

Serious Gravity 5 1 instance 2 exposed
Issued
May 24, 2024
Abate by
Jun 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components and were not removed from service:  a) On March 12, 2024, and times prior an employee used an unserviceable energy absorbing lanyard as part of a personal fall arrest system.  The shock pack and controlled tear stitching were removed from the lanyard.   Note) Certification of corrective action is required for this item.
Recent events (1)
  • — Z (S) $0

1926.503 A02 III

Serious Gravity 5 4 instances 2 exposed
Issued
May 24, 2024
Abate by
Jun 13, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee had been trained, as necessary, by a competent person qualified in the correct procedures for the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used:  a) On March 12, 2024, and times prior an employee used an unserviceable energy absorbing lanyard. The shock pack and controlled tear stitching had been removed.  The employee did not recognize the hazards of using unserviceable personal fall arrest components or the actions needed to correct the hazard.   b) On March 12, 2024, two employees were attached to the same anchor point.  The employees did not recognize the hazards of not properly using personal fall arrest or the actions needed to correct the hazard.   c) On March 12, 2024, and times prior employees used fall protection components that were not compatible, in that rebar hooks were attached to snap-hooks.  The employees did not recognize the hazard of not properly using personal fall arrest or the actions needed to correct the hazard.   d) On March 12, 2024, and times prior an employee used the snap-hook attached back onto the lanyard as part of the anchor point.  The employee did not recognize the hazard of not properly using personal fall arrest or the actions needed to correct the hazard.    Note) Certification of corrective action is required for this item.
Recent events (1)
  • — Z (S) $0

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
May 24, 2024
Abate by
May 31, 2024
Penalty
Initial $3,702 · Current $3,702
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) On March 12, 2024 employees performing framing activities used powered tools without protective eye wear that was ANSI Z-87 compliant.    Note) Certification of corrective action is required for this item.
Recent events (1)
  • — Z (S) $3702

1926.416 E01

Serious Gravity 1 1 instance 1 exposed
Issued
May 24, 2024
Abate by
May 31, 2024
Penalty
Initial $3,702 · Current $3,702
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) On March 12, 2024 a power cord coming from the temporary power pole installation had damaged outer insulation, which exposed the inner (insulated/un-insulated) energized conductors.  Note) Certification of corrective action is required for this item.
Recent events (1)
  • — Z (S) $3702