EL PASO, TX —
OSHA Inspection: EL PASO KING'S PLUMBING, LLC
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of EL PASO KING'S PLUMBING, LLC in 208 ISELA RUBALCABA, EL PASO, TX 79932 (NAICS 238220). OSHA activity number 347342727.
Where did this inspection happen?
- Establishment
- EL PASO KING'S PLUMBING, LLC
- Site address
- 208 ISELA RUBALCABA
- City
- EL PASO
- State
- TX
- ZIP
- 79932
- Mailing
- 635 ENDWALL ST., EL PASO, TX 79928
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $4148.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1):Each employee on a walking/working surface having an unprotected side or edge was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system. On or about March 12, 2024, employees were observed working by the edge of an open trench which was six or more feet deep without any type of fall protection.
Recent events (2)
- — I (S) $2500
- — Z (S) $4148
1926.652 C
- Issued
- Abate by
- Penalty
- Initial $4148.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.652(c): Designs of support systems shield systems, and other protective systems were not selected and constructed by the employer or his designee and was not in accordance with the requirements of paragraph (c)(1); or, in the alternative, paragraph (c)(2); or, in the alternative, paragraph (c)(3); or, in the alternative, paragraph (c)(4). On or about March 12, 2024, the trench shoring system used to protect employees working inside the trench uncovering a city sewer main line located at northwest side of an apartment complex, were not selected and constructed in accordance to requirements of paragraphs (c)(1), (c)(2), (c)(3), or (c)(4), of 29 CFR 1926.652.
Recent events (2)
- — I (S) $2500
- — Z (S) $4148
1926.652 B03 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.652(b)(3)(iii): Tabulated data, identifying the registered professional engineer who approved the data, was not maintained at the jobsite during construction of the protective system. After that time, that data was not made available to the Secretary when requested. On or about March 12, 2024, a trench dug on a two lane public street located by the northwest side of an apartment's complex where engineering or trench tabulated data used on the shoring system was not maintained at jobsite or made available for Compliance Officer's review.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 I03
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.651(i)(3):Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures. On or about March 12, 2024, employees were observed uncovering a city's street main drainage pipe inside an open trench without cave-in protection where vehicular traffic was allowed adjacent to the trench.
Recent events (2)
- — I (S) $3000
- — Z (S) $4839
1926.1053 B01
- Issued
- Penalty
- Initial $4148.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed On or about March 12, 2024, a ladder used to climb into and out of a trench that is located in the northwest of an apartment complex did not extend at least three feet above the landing surface.
Recent events (2)
- — I (S) $2500
- — Z (S) $4148
1926.1053 B04
- Issued
- Penalty
- Initial $2351.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed. On or about March 12, 2024, employees who were working to uncover the city main sewer line inside the north part of the trench were observed climbing in and out of a trench using a folded step ladder.
Recent events (2)
- — I (S) $1500
- — Z (S) $2351
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347342727.