CUMMING, GA —
OSHA Inspection: CLADDING & COMPONENT SOLUTIONS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of CLADDING & COMPONENT SOLUTIONS, INC. in 2705 NORTHGATE COURT, CUMMING, GA 30041 (NAICS 332999). OSHA activity number 347349540.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLADDING & COMPONENT SOLUTIONS, INC.
- Site address
- 2705 NORTHGATE COURT
- City
- CUMMING
- State
- GA
- ZIP
- 30041
- Mailing
- 2705 NORTHGATE COURT, CUMMING, GA 30041
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 45
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.253 B04 I
- Issued
- Aug 19, 2024
- Penalty
- Initial $6,453 · Current $3,872 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i):Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire a) Back of the warehouse - On or about 03/15/2024, and at times prior, the employer exposed employees to fire hazards in that, the employer failed to ensure that oxygen cylinders were not stored next to the acetylene cylinder inside the warehouse when employees were performing welding operation.
Recent events (2)
- — I (S) $3871.8
- — Z (S) $6453
1910.253 B02 II
- Issued
- Aug 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(ii):Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Back of the warehouse - On or about 03/15/2024, and at times prior, the employer exposed employees to struck by hazards in that, the employer failed to ensure that four gas cylinders were stored securely and away from bay door when employees were performing welding operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B02 IV
- Issued
- Aug 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) Back of warehouse - On or about 03/15/2024, and at times prior, the employer exposed employees to fire hazards in that, the employer failed to ensure that oxygen cylinder valve protection caps were in place while employees were performing welding operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Aug 19, 2024
- Abate by
- Sep 13, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Warehouse/Welding Department - On or about 03/15/2024 and at times prior, the employer exposed employees to respiratory hazards in that, the employer failed to ensure that employees were provided with a written respiratory protection program when employees were using 3M Half-mask respirators while performing welding operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Aug 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Warehouse/Welding Department - On or about 03/15/2024 and at times prior, the employer exposed employees to respiratory hazards in that, the employer failed to ensure that employees were medically evaluated prior to initial use of respirators when employees were using 3M Half-mask respirators while conducting welding operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 F02
- Issued
- Aug 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) Warehouse/Welding Department - On or about 03/15/2024 and at times prior, the employer exposed employees to respiratory hazards in that, the employer failed to ensure that employees were fit tested prior to initial use of the tight-fitting facepiece respirators when employees were performing welding operation and using 3M Half-mask respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347349540.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.