SHEBOYGAN, WI —
OSHA Inspection: VANRITE PLUMBING INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VANRITE PLUMBING INC in 1114 - 1209 SOUTH 11TH ST, SHEBOYGAN, WI 53081 (NAICS 238220). OSHA activity number 347356958.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VANRITE PLUMBING INC
- Site address
- 1114 - 1209 SOUTH 11TH ST
- City
- SHEBOYGAN
- State
- WI
- ZIP
- 53081
- Mailing
- 2229 CTY RD QQ, GREEN BAY, WI 54311
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Jul 12, 2024
- Penalty
- Initial $3,457 · Current $1,729 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, employees were exposed to overhead struck-by hazards working in area with an excavator without using hard hats.
Recent events (2)
- — I (S) $1728.5
- — Z (S) $3457
1926.102 A01
- Issued
- Jul 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, employees were exposed to struck-by hazards while using power tools without wearing eye protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.251 A06
- Issued
- Jul 12, 2024
- Penalty
- Initial $2,765 · Current $1,383 Reduced
General-duty citation text
29 CFR 1926.251(a)(6): Rigging equipment for material handling. "Inspections." Each day before being used, the sling and all fastenings and attachments shall be inspected for damage or defects by a competent person designated by the employer. Additional inspections shall be performed during sling use, where service conditions warrant. Damaged or defective slings shall be immediately removed from service. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, the employer did not ensure that a damaged four-legged sling used to hoist a trench shield was removed from service prior to employees working on the site. No gate on a chain hook and gate not working on the swivel hoist hook.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1926.251 A02 I
- Issued
- Jul 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.251(a)(2)(i): Rigging equipment for material handling. Employers must ensure that rigging equipment has permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, the employer did not ensure that four-legged slings had permanently affixed identification and safe working load information on the chains. Two slings available for use on the site.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 J02
- Issued
- Jul 12, 2024
- Penalty
- Initial $3,457 · Current $1,729 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, an employee was exposed to crushing and struck-by hazards while working from inside an excavation at 5.5 feet deep without the spoil pile back two feet from the top edge.
Recent events (2)
- — I (S) $1728.5
- — Z (S) $3457
1926.651 K01
- Issued
- Jul 12, 2024
- Abate by
- Aug 16, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. On or about March 19, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, the employer did not ensure that a competent person was performing frequent and regular inspections that could have recognized the potential engulfment hazard associated with employees working from inside excavations at greater than 5 feet deep without using cave-in protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Jul 12, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section. On or about March 19, 2024, at 1114-1209 S 11th Street in Sheboygan, Wisconsin, employees were exposed to potential struck-by hazards working from inside excavations at greater than 5.5 feet deep without using cave-in protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Vanrite Plumbing INC
View Vanrite Plumbing INC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347356958.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.