Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLORES LLC PAINTING & DRYWALL

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FLORES LLC PAINTING & DRYWALL in 114 RIVERHEIGHTS DR, NEW RICHMOND, OH 45157 (NAICS 238320). OSHA activity number 347357493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flores LLC Painting & Drywall — free Get an email when a new federal OSHA severe-injury report for Flores LLC Painting & Drywall is published. One employer, no account, unsubscribe in one click.
Site address
114 RIVERHEIGHTS DR
City
NEW RICHMOND
State
OH
ZIP
45157
Mailing
1185 HARMON AVE, HAMILTON, OH 45011
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.134 D01 III

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Penalty
Initial $4,148 · Current $2,000 Reduced
29 CFR  1910.134(d)(1)(iii): The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.  a) On or about March 19, 2024, at the jobsite located at 114 Riverheights Dr. New Richmond, Ohio, the employer did not evaluate employee exposure to carbon monoxide prior to them working inside a  residential home with a propane-powered torpedo heater running in an adjacent attached garage.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4148

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Abate by
May 31, 2024
Penalty
Initial $4,148 · Current $0 Reduced
29 CFR  1910.1200(e)(1):Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the requirements of 1910.1200(e)(1)(i) and (e)(1)(ii).  a)On or about March 19, 2024, the employer had not developed, implemented, or maintained a written hazard communication program for employees exposed to chemicals and gases, such as but limited to Carbon monoxide (asphyxiant).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4148

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Abate by
May 31, 2024
Penalty
Initial $4,148 · Current $0 Reduced
29 CFR  1910.1200(h)(1):Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.  a) On or about March 19, 2024, the employer did not train employees on the chemicals and poisonous gases in their work area, such as carbon monoxide, that was found in the exhaust of the propane powered LB White tradesman 170 Ultra torpedo heater (Model: CP170 Serial # AC1022655) being used to heat the work area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4148

1910.1200 H03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Abate by
May 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(3)(i): Training. Employee training shall include at least: Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.).  a) On or about March 19, 2024, employees were not trained on the continuous monitoring devices located inside the residential home, in that employees did not recognize that the First Alert AC Powered Smoke and Carbon Monoxide alarm was alarming due to the presence of carbon monoxide (asphyxiant) in the work area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Abate by
May 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(3)(ii): Training. Employee training shall include at least: The physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area.  a) On or about March 19, 2024, the employer did not train employees on the health hazards associated with the chemicals and poisonous gases in their work area, such as carbon monoxide (asphyxiant), that was found in the exhaust of the propane powered LB White tradesman 170 Ultra torpedo heater (Model: CP170 Serial # AC1022655) being used to heat the work area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 26, 2024
Penalty
Initial $4,148 · Current $0 Reduced
29 CFR  1926.20(b)(2): Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a) On or about March 19, 2024, the employer did not conduct adequate inspections of the job site. As a result, employees were exposed to chemical hazards including carbon monoxide while utilizing a propane powered LB White tradesman 170 Ultra torpedo heater (Model: CP170 Serial # AC1022655).
Recent events (2)
  • — I (S) $0
  • — Z (S) $4148

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347357493.