HOUSTON, TX —
OSHA Inspection: MANDRELS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MANDRELS, LLC in 9107 LEY RD., HOUSTON, TX 77078 (NAICS 332312). OSHA activity number 347358525.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANDRELS, LLC
- Site address
- 9107 LEY RD.
- City
- HOUSTON
- State
- TX
- ZIP
- 77078
- Mailing
- 9107 LEY RD., HOUSTON, TX 77078
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 13
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- May 29, 2024
- Penalty
- Initial $6,452 · Current $4,516 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about March 16, 2024, at the machine shop an employee was utilizing a Lagun drill press without adequate machine guarding while drilling holes in a lug part.
Recent events (2)
- — I (S) $4516.4
- — Z (S) $6452
1910.242 B
- Issued
- May 29, 2024
- Penalty
- Initial $3,687 · Current $2,581 Reduced
General-duty citation text
29 CFR 1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about March 16, 2024, at the machine shop employees were exposed to struck-by hazards as compressed blow down air used at drill presses was not reduced to less than 30 p.s.i.
Recent events (2)
- — I (S) $2580.9
- — Z (S) $3687
1910.305 G02 III
- Issued
- May 29, 2024
- Penalty
- Initial $4,610 · Current $3,227 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about March 16, 2024, at the machine shop employees were exposed to an electrocution hazard as there was a power cord of a drill press that did not have proper strain relief.
Recent events (2)
- — I (S) $3227
- — Z (S) $4610
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347358525.