Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IBN CONSTRUCTION CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of IBN CONSTRUCTION CORPORATION in 823- 825 SOUTH 18TH ST, NEWARK, NJ 07108 (NAICS 238130). OSHA activity number 347358707.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IBN Construction Corporation — free Get an email when a new federal OSHA severe-injury report for IBN Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
823- 825 SOUTH 18TH ST
City
NEWARK
State
NJ
ZIP
07108
Mailing
49 HERMON STREET, NEWARK, NJ 07105
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
15
Ownership type
A

8 citations on file for this inspection.

1903.19 D01

Deleted Other-than-serious 1 instance 15 exposed
Issued
Apr 17, 2025
Abate by
Apr 30, 2025
Penalty
Initial $584 · Current $0 Reduced
29 CFR  1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  a. 823 South 18th St, Newark NJ  The employer did not provide abatement certification and documentation for inspection number 1735870 citation # 1 Item # 1, Citation # 1 item # 3a, Citation 1 item # 3b, Citation #1 item # 4,  Citation # 1 Item # 5, and Citation # 1 item # 6 pertaining to 1926.405(a)(2)(ii)(A), 1926.405(j)(1)(i), 1926.405(j)(1)(ii), 1926.416(a)(1), 1926.501(b)(4)(i), and 1926.1052(c)(1)(i)  respectively which were due on 10-04-2024. The employer was issued the citation and notification of penalty on 09-19-2024.  Violation occurred on about 02-18-2025
Recent events (2)
  • — I (O) $0
  • — Z (O) $584

1926.405 A02 II A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $7,098 · Current $2,000 Reduced
29 CFR  1926.405(a)(2)(ii)(A): Temporary wiring feeders did not originate in a distribution center:  a. 823 South 18th St, Newark NJ  The employer did not have temporary wiring feeders originate in a distribution center.  Employees used a duplex receptacle connected to a street light. The employees attached extension cords to the duplex outlets to power tools and equipment at the residential building under construction, exposing them to electrical hazards at 120 volts.  Violation observed on 03/20/24
Recent events (2)
  • — I (S) $2000
  • — Z (S) $7098

1926.405 A02 II I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Penalty
Initial $7,098 · Current $1,000 Reduced
29 CFR  1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  a. 823- 825 South 18th St, Newark NJ  The employer did not provide protection from damage to an extension cord that passed through a window with the sash lowered onto the cord. The employees used the extension cord to power tools for the residential building under construction.  Violation observed on 03/20/24
Recent events (2)
  • — I (S) $1000
  • — Z (S) $7098

1926.405 J01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $7,098 · Current $2,000 Reduced
29 CFR  1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:    a. 823 South 18th St, Newark NJ  The employer allowed employees to utilize a 120 volt duplex receptacle connected to a street light pole to supply power to an extension cord used for operating power tools at a residential building under construction. The duplex receptacle was not elevated above the floor and had exposed live parts, exposing the employees to electrical hazards.   Violation observed on 03/20/24
Recent events (2)
  • — I (S) $2000
  • — Z (S) $7098

1926.405 J01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported:  a. 823 South 18th St, Newark NJ  The employer allowed employees to utilize a 120 volt duplex receptacle connected to a streetlight pole to supply power to an extension cord used for operating power tools at a residential building under construction. The duplex receptacle was not securely supported exposing the employees to electrical hazards.   Violation observed on 03/20/24
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $7,098 · Current $1,500 Reduced
29 CFR  1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:    a. 823 South 18th St, Newark NJ  The employer allowed employees to work in close proximity to an energized, unguarded 240-volt electrical line from the street transformer pole that passed through the residential building under construction, exposing them to electrical hazards.   Violation observed on 03/20/24
Recent events (2)
  • — I (S) $1500
  • — Z (S) $7098

1926.501 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $7,098 · Current $2,000 Reduced
29 CFR  1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  a. 823- 825 South 18th St, Newark NJ  The employer failed to protect its employees working on a residential building under construction from falling through an uncovered hole on the third floor. The employees were exposed to a fall hazard of approximately 10 feet below.    Violation observed on 03/20/24
Recent events (2)
  • — I (S) $2000
  • — Z (S) $7098

1926.1052 C01 I

Serious Gravity 10 2 instances 4 exposed
Issued
Sep 19, 2024
Abate by
Oct 4, 2024
Penalty
Initial $7,098 · Current $1,500 Reduced
29 CFR  1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  Location : 825 South 18th St, Newark NJ  a) The employer failed to install at least one handrail on a staircase with more than four risers at a residential building under construction. The stairs from the first to the third floor of the two buildings do not have handrails, exposing workers to fall hazards.  Violation observed on 03/20/24
Recent events (2)
  • — I (S) $1500
  • — Z (S) $7098

View IBN Construction Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347358707.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.