NEW LONDON, WI —
OSHA Inspection: WOHLT CREAMERY, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WOHLT CREAMERY, LLC in 1005 ORVILLE DRIVE, NEW LONDON, WI 54961 (NAICS 311513). OSHA activity number 347360901.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WOHLT CREAMERY, LLC
- Site address
- 1005 ORVILLE DRIVE
- City
- NEW LONDON
- State
- WI
- ZIP
- 54961
- Mailing
- 1005 ORVILLE DRIVE, NEW LONDON, WI 54961
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 78
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.28 B06 I
- Issued
- Aug 16, 2024
- Penalty
- Initial $4,839 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment is protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard: On or about April 4, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Second Floor Cook Room; an unguarded steam pipe adjacent to the mobile stairs on the backside of Cooker 1 was not protected to prevent employee exposure to thermal hazards.
Recent events (3)
- — F (O) $3000
- — C (S) $4839
- — Z (S) $4839
1910.147 D
- Issued
- Aug 16, 2024
- Abate by
- Apr 30, 2025
- Penalty
- Initial $6,453 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about March 20, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Packaging Department; employees were exposed to machine hazards associated with moving parts when they engaged in clearing jammed boxes on the Hart filling machines. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to bypass machine guarding. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (3)
- — F (S) $4000
- — C (S) $6453
- — Z (S) $6453
1910.212 A01
- Issued
- Aug 16, 2024
- Abate by
- Sep 30, 2025
- Penalty
- Initial $6,453 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.: a) On or about March 20, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Second Floor Cook Room; the infeed conveyor on the Cooker 1 was not guarded on the underside to prevent employee exposure to the in running nip point hazard. b) On or about April 4, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Second Floor Cook Room; the infeed conveyor on the Cooker 2 was not guarded on the underside to prevent employee exposure to the in running nip point hazard.
Recent events (3)
- — F (O) $3000
- — C (S) $6453
- — Z (S) $6453
1910.303 B02
- Issued
- Aug 16, 2024
- Abate by
- Sep 4, 2024
- Penalty
- Initial $4,839 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling: a) On or about March 20, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Maintenance Shop; a relocatable power tap was used as permanent wiring and affixed to the east block wall. b) On or about March 20, 2024, at a workplace located at 1005 Orville Drive, New London, Wisconsin in the Second Floor Cook Room; an energized wall outlet along the outer perimeter of the Cook Room was missing a portion of the outlet face, exposing the internal electrical components.
Recent events (3)
- — F (O) $2000
- — C (S) $4839
- — Z (S) $4839
More inspections at Wohlt Creamery, LLC
View Wohlt Creamery, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347360901.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.