ST THOMAS, VI —
OSHA Inspection: PUEBLO SUPERMARKET - SUBBASE (WORLD FRESH MARKET, LLC)
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PUEBLO SUPERMARKET - SUBBASE (WORLD FRESH MARKET, LLC) in #2 SUB BASE, ST THOMAS, VI 00802 (NAICS 445110). OSHA activity number 347361446.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- #2 SUB BASE
- City
- ST THOMAS
- State
- VI
- ZIP
- 00802
- Mailing
- PO BOX 10829, ST THOMAS, VI 00801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 445110
- Employees
- 75
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.178 L06
- Issued
- Sep 16, 2024
- Abate by
- Oct 11, 2024
- Penalty
- Initial $11,201 · Current $7,281 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a. On or March 21, 2024, at the receiving area. Employees were exposed to a struck by hazard while loading, unloading and storing pallets of merchandise when using power industrial trucks such as Mitsubishi (LPG) FGC15 and Yale electrical pallet jack MPB045-VGN. The employer did not certify that each operator had been trained and evaluated. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (S) $7280.65
- — Z (S) $11201
1910.303 G01
- Issued
- Sep 16, 2024
- Penalty
- Initial $4,760 · Current $3,094 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: On or about March 21, 2024, electrical service panels were not readily accessible in the following areas: a. At the janitorial room area, materials such as broom handles, broom, plastic closed dustpan, paint trays, and wet floor safety cone were stored below two electrical panels. b. At the IT room area, a work station table with computer and monitor and other similar computer equipment were placed in front of four electrical panels. c. At the receiving area, a large metal storage cabinet, cardboard box and plastic crate were placed in front of an electrical panel. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer within 24 hours of the inspection.
Recent events (2)
- — I (S) $3094
- — Z (S) $4760
1910.305 C04
- Issued
- Sep 16, 2024
- Penalty
- Initial $4,760 · Current $3,094 Reduced
General-duty citation text
29 CFR 1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface: a. On or about March 21, 2024, at the 1st floor janitorial room area. Employees are exposed to an electric shock from a light switch with exposed conductors that did not have a face plate cover. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer within 24 hours of the inspection.
Recent events (2)
- — I (S) $3094
- — Z (S) $4760
1910.305 G01 IV A
- Issued
- Sep 16, 2024
- Penalty
- Initial $4,760 · Current $3,094 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about March 21, 2024, extension cords and relocatable power taps (RPT) were used as a substitute for fixed wiring to provide power as follows: a. At the pricing office areas, an extension cord was series connected to a relocatable power tap (RPT) to provide power to computer equipment and printers. b. At the receiving area, an extension cord was series connected to a relocatable power tap (RPT) onto a second a relocatable power tap (RPT) to charge a Yale electrical pallet jack MPB045-VGN. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer within 24 hours of the inspection.
Recent events (2)
- — I (S) $3094
- — Z (S) $4760
1910.305 G01 IV B
- Issued
- Sep 16, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: On or about March 21, 2024, extension cords used as permanent power source and were run through holes in ceiling and walls as follows: a. At the pricing office areas, extension cords were used to provide power to computer equipment and ran through holes in the ceiling in several locations. b. At the conference room area, extension cords were used to provide power to phone equipment and ran through holes in the ceiling. c. At the IT room area, two red extension cords were used to provide power to computer equipment in the pricing office area and ran through holes in the ceiling and plugged in two four plugs receptacles in this area. NOTE 1: Certification and documentation of abatement must be submitted for Instance a as required by 29 CFR 1903.19(c) and (d), respectively. NOTE 2: Certification of abatement is not required for Instances b and c as abatement was documented by the compliance safety and health officer within 24 hours of the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 B06
- Issued
- Sep 16, 2024
- Abate by
- Oct 11, 2024
- Penalty
- Initial $1,000 · Current $650 Reduced
General-duty citation text
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1 and April 30: a. On or about March 21, 2024, at the administrative office area. The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for calendar year 2023 was not posted between February 1 and April 30, 2024. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (O) $650
- — Z (O) $1000
1910.157 C01
- Issued
- Sep 16, 2024
- Penalty
- Initial $891 · Current $579 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries a. On or about March 21, 2024, at the front office area, two fully-charged Class ABC 5-lbs and 2.5-lbs portable fire extinguishers were not mounted and were placed at floor level next to a workstation and obstructed by wrapped coins bag and sweeping tools such as broom and dustpan. NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer within 24 hours of the inspection.
Recent events (2)
- — I (O) $579.15
- — Z (O) $891
1910.1200 E01
- Issued
- Sep 16, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $1,048 · Current $681 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or March 21, 2024, at the receiving area. The employer did not develop and implement their written hazard communication program to ensure having safety data sheets for compressed gases such as propane (LPG) when employees replaced empty tanks with full ones during Mitsubishi forklift maintenance operations. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (O) $681.2
- — Z (O) $1048
1910.1200 G01
- Issued
- Sep 16, 2024
- Abate by
- Oct 11, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use a. On or about March 21, 2024, at the receiving area. The employer did not have a safety data sheet for each hazardous chemical such as propane (LPG) compressed gas used and/or handled by employees when replacing empty tanks with full ones during Mitsubishi forklift maintenance operations. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c) and (d), respectively.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 445110)
More inspections in VI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347361446.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.