ANDREWS, TX —
OSHA Inspection: MURPHY WELL CONTROL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MURPHY WELL CONTROL, LLC in 1670 S US HIGHWAY 385, ANDREWS, TX 79714 (NAICS 213112). OSHA activity number 347362063.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MURPHY WELL CONTROL, LLC
- Site address
- 1670 S US HIGHWAY 385
- City
- ANDREWS
- State
- TX
- ZIP
- 79714
- Mailing
- PO BOX 51053, MIDLAND, TX 79710
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Sep 3, 2024
- Abate by
- Nov 27, 2024
- Penalty
- Initial $9,680 · Current $5,808 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: On or about March 21, 2024, at the Murphy Well Control yard(s) hydrotesting area, employee(s) performing maintenance and service activities on assigned equipment, such as but not limited to, pressure testing hydraulic pumps of fracking equipment, were not trained to required authorized employee level which includes means and methods necessary for energy isolation and control.
Recent events (2)
- — I (S) $5808
- — Z (S) $9680
1910.147 C06 II
- Issued
- Sep 3, 2024
- Abate by
- Nov 27, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections of the energy control procedure have been performed On or about March 21, 2024, at the Murphy Well Control yard(s) hydrotesting area, employee(s) performing maintenance and service activities on assigned equipment, such as but not limited to, pressure testing hydraulic pumps of fracking equipment, were not periodically inspected as required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347362063.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.