Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MURPHY WELL CONTROL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MURPHY WELL CONTROL, LLC in 1670 S US HIGHWAY 385, ANDREWS, TX 79714 (NAICS 213112). OSHA activity number 347362063.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Murphy Well Control, LLC — free Get an email when a new federal OSHA severe-injury report for Murphy Well Control, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1670 S US HIGHWAY 385
City
ANDREWS
State
TX
ZIP
79714
Mailing
PO BOX 51053, MIDLAND, TX 79710
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
6
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 3, 2024
Abate by
Nov 27, 2024
Penalty
Initial $9,680 · Current $5,808 Reduced
29 CFR  1910.147(c)(7)(i)(A): Each authorized employee had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:   On or about March 21, 2024, at the Murphy Well Control yard(s) hydrotesting area, employee(s) performing maintenance and service activities on assigned equipment, such as but not limited to, pressure testing hydraulic pumps of fracking equipment, were not trained to required authorized employee level which includes means and methods necessary for energy isolation and control.
Recent events (2)
  • — I (S) $5808
  • — Z (S) $9680

1910.147 C06 II

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 3, 2024
Abate by
Nov 27, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii): The employer did not certify that the periodic inspections of the energy control procedure have been performed   On or about March 21, 2024, at the Murphy Well Control yard(s) hydrotesting area, employee(s) performing maintenance and service activities on assigned equipment, such as but not limited to, pressure testing hydraulic pumps of fracking equipment, were not periodically inspected as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347362063.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.