OSHA Inspection: ADOLVA DE LA ROSA MILIAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADOLVA DE LA ROSA MILIAN in 4903 NEW CARLISLE PIKE, SPRINGFIELD, OH 45504 (NAICS 238160). OSHA activity number 347364317.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adolva DE LA Rosa Milian — free Get an email when a new federal OSHA severe-injury report for Adolva DE LA Rosa Milian is published. One employer, no account, unsubscribe in one click.
Site address
4903 NEW CARLISLE PIKE
City
SPRINGFIELD
State
OH
ZIP
45504
Mailing
315 BRANDT PIKE, DAYTON, OH 45404
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 11, 2024
Abate by
Jul 31, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.   a) On or about March 20, 2024, the employer did not ensure employees were protected from fall hazards while installing roofing materials on a residential roof with a height of 9 feet 4 inches and a 4-12 pitch, exposing employees to fall hazards.
Recent events (1)
  • — Z (S) $4839

1926.503 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 11, 2024
Abate by
Jul 31, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.503(a)(1):The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  a.) On or about March 20, 2024, the employer failed to provide fall protection training to employees who were exposed to fall hazards while installing roofing materials on a residential roof with a height of 9 feet 4 inches and a 4-12 pitch
Recent events (1)
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 11, 2024
Abate by
Aug 6, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   a) On or about March 20, 2024, the employer did not ensure that the side rails of a portable extension ladder, being utilized by employees re-roofing a residential roof with a fall height of 9'4" to the ground, extended at least 3 feet above the upper landing surface. As a result employees were exposed to a fall hazard.
Recent events (1)
  • — Z (S) $4839

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347364317.