Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ORION FIRE SYSTEMS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ORION FIRE SYSTEMS INC. in 1590 N ROBERTS RD NW SUITE 210, KENNESAW, GA 30144 (NAICS 922160). OSHA activity number 347365694.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orion Fire Systems INC. for free Get an email when a new federal OSHA severe-injury report for Orion Fire Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
1590 N ROBERTS RD NW SUITE 210
City
KENNESAW
State
GA
ZIP
30144
Mailing
1590 NORTH ROBERTS ROAD SUITE 210, KENNESAW, GA 30144
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922160
Employees
7
Ownership type
Private (A)

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $3,457 · Current $2,074 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Maintenance Warehouse: On or about March 22, 2024, and at times prior, the employer exposed employees to chemical burns, in that a safety shower and eye wash station capable of providing at least 15 minutes of water flow was not available for employees using ZEP CON IND PURPLE DEGREASER. The SPEAKMAN GRAVITYFLO SE 4400-9 GALLON eye wash station was placed on a storage rack at the back of the facility and was covered in dust.
Recent events (2)
  • · I (S) $2074.2
  • · Z (S) $3457

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:  a) Maintenance Warehouse: On or about March 22, 2024, and at times prior, the employer exposed employees to chemical, respiratory and struck-by hazards, in that the employer did not verify that a hazard assessment had been completed while employees perform emergency exit light repair, inspections, certification and maintenance of fire extinguishers.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   a) Maintenance Warehouse: On or about March 22, 2024, and at times prior, the employer exposed employees to respiratory hazards, in that employees were provided tight fitting 3M 8511 N95 and 3M half face elastomeric respirators with cartridges, without establishing a written respiratory protection program while employees perform emergency exit light repair, inspection, certification and maintenance of fire extinguishers.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Sep 13, 2024
Abate by
Oct 11, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Maintenance Warehouse: On or about March 22, 2024, and at times prior, the employer exposed employees to chemical hazards, in that a written hazard communication program was not developed and implemented for employees using hazardous chemicals such as but not limited to ZEP Degreaser, Wet Chemical Solution and ABC Dry Chemical Fire extinguishant.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347365694.