Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUMEN TECHNOLOGIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LUMEN TECHNOLOGIES in S BROADWAY AVE, BOISE, ID 83702 (NAICS 517311). OSHA activity number 347367674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lumen Technologies — free Get an email when a new federal OSHA severe-injury report for Lumen Technologies is published. One employer, no account, unsubscribe in one click.
Establishment
LUMEN TECHNOLOGIES
Site address
S BROADWAY AVE
City
BOISE
State
ID
ZIP
83702
Mailing
23315 66TH AVE. S, KENT, WA 98032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
517311
Employees
567
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 7, 2024
Abate by
Jun 3, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a) On March 22, 2024 and at times prior thereto, an employee was not protected from cave-in hazards when working in an excavation with near vertical walls, measuring approximately 4' 6" deep, 7' wide and 18' long.
Recent events (2)
  • — I (O) $0
  • — Z (S) $16131

1926.651 C02

Serious Gravity 5 1 instance 4 exposed
Issued
May 7, 2024
Abate by
Jun 3, 2024
Penalty
Initial $10,140 · Current $6,033 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  (a) On March 22, 2024, and at times prior thereto, employees worked in an excavation with near vertical walls, measuring approximately 4' 6" deep, 7' wide and 18' long.
Recent events (2)
  • — I (S) $6033
  • — Z (S) $10140

1926.651 I03

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
May 7, 2024
Abate by
Jun 3, 2024
Penalty
Initial $16,131 · Current $0 Reduced
29 CFR  1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:  (a) On March 22, 2024 and at times prior thereto, employee were not protected from cave-in hazards when splicing cable in an excavation which had sloughed off enough to have undercut the pavement roadway situated on the west side of the excavation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1926.651 K01

Serious Gravity 10 1 instance 4 exposed
Issued
May 7, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $8,766
29 CFR  1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.   a) On March 22, 2024 and at times prior thereto, employee were not protected from cave-in hazards when splicing cable in an excavation with near vertical walls, measuring approximately 4' 6" deep, 7' wide and 18' long.
Recent events (2)
  • — I (S) $8766
  • — Z (S) $0

1926.652 A01

Serious Gravity 10 1 instance 4 exposed
Issued
May 7, 2024
Abate by
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c)  a) On March 22, 2024 and at times prior thereto, employees were not protected from cave-in hazards when working in an excavation with near vertical walls, measuring approximately 4' 6" deep, 7' wide and 18' long.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Lumen Technologies's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347367674.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.