OSHA Inspection: VALMONT INDUSTRIES, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of VALMONT INDUSTRIES, INC. in 25055 ALLIANCE DRIVE, CLAREMORE, OK 74019 (NAICS 332312). OSHA activity number 347371114.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valmont Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Valmont Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
25055 ALLIANCE DRIVE
City
CLAREMORE
State
OK
ZIP
74019
Mailing
25055 ALLIANCE DRIVE, CLAREMORE, OK 74019
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
121
Ownership type
A

7 citations on file for this inspection.

1910.29 B03

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Sep 10, 2024
Abate by
Oct 11, 2024
Penalty
Initial $9,218 · Current $7,000 Reduced
29 CFR 1910.29(b)(3): The employer did not ensure that guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail.   On or about March 21, 2024 and at times prior thereto, by the #1 caustic tank in plant 1, employees perform dipping operations and the guardrails surrounding the caustic tank were damaged.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $9218

1910.184 C14

Deleted Serious Gravity 5 5 instances 5 exposed
Issued
Sep 10, 2024
Abate by
Oct 4, 2024
Penalty
Initial $13,828 · Current $0 Reduced
29 CFR  1910.184(c)(14): Employers used lift devices without affixed and legible identification markings.                                                                                                                                                                                                                                                                                                    On or about March 21, 2024 and at times prior thereto, throughout the facility, employees use an overhead crane to lift various materials and the hooks, attached to the crane hook, did not have permanently affixed legible identification markings stating the size and rated capacity.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13828

1910.184 E01

Deleted Serious Gravity 5 5 instances 4 exposed
Issued
Sep 10, 2024
Abate by
Oct 4, 2024
Penalty
Initial $13,828 · Current $0 Reduced
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach.                                                                                                                                                                                                                                                                                                   On or about March 21, 2024 and at time prior thereto, throughout the facility, the chain slings used by employees to lift and move material did not have affixed legible identification markings stating the size, grade, rated capacity, and reach.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13828

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 10, 2024
Abate by
Oct 4, 2024
Penalty
Initial $9,218 · Current $7,000 Reduced
29 CFR 1910.253 (b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m).  On or about March 24, 2024, behind plant #2, stored cylinders of oxygen and acetylene were not separated by at least 20 feet.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $9218

1910.22 D01

Serious Gravity 5 3 instances 3 exposed
Issued
Sep 10, 2024
Abate by
Oct 4, 2024
Penalty
Initial $69,140 · Current $10,000 Reduced
29 CFR 1910.22(d)(1): Walking-working surfaces were not inspected, regularly and as necessary, and maintained in a safe condition;    a.) On or about June 20, 2024 and at times prior thereto, between the caustic #1 and caustic #2 tanks in plant 1, employees walked on a grating-to-concrete walking surface that was not inspected, regularly and as necessary, and maintained in a safe condition since the grating had become detached and elevated above the concrete walking surface.   b.) On or about June 20, 2024 and at times prior thereto, between the acid #1 and acid #2 tanks in plant 1, employees walked on a grating-to-concrete walking surface that was not inspected, regularly and as necessary, and maintained in a safe condition since the grating had become detached and elevated above the concrete walking surface.   c.) On or about June 20, 2024 and at times prior thereto, in front of the kettle tank in plant 1, employees walked/worked on a diamond plating-to-concrete flooring that was not inspected, regularly and as necessary, and maintained in a safe condition since the diamond plating had become detached and elevated above the concrete walking surface.
Recent events (2)
  • — I (S) $10000
  • — Z (R) $69140

1910.157 A

Other-than-serious 1 instance 2 exposed
Issued
Sep 10, 2024
Abate by
Oct 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.     On or about March 21, 2024, in plant #2 by the kettle, employees worked in an area where a mounted fire extinguisher was blocked by equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.212 A05

Other-than-serious 1 instance 2 exposed
Issued
Sep 10, 2024
Abate by
Sep 27, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level.                                                                                                             On or about March 21, 2024, in plant #1 by the kettle, employees were in use of a floor fan that has metal blades and the guard had openings more than ? inch.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Valmont Industries, INC.'s full OSHA safety record →