Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FREEPORT MONUMENT, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FREEPORT MONUMENT, LLC in 344 SECOND STREET, FREEPORT, PA 16229 (NAICS 423990). OSHA activity number 347376386.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Freeport Monument, LLC — free Get an email when a new federal OSHA severe-injury report for Freeport Monument, LLC is published. One employer, no account, unsubscribe in one click.
Site address
344 SECOND STREET
City
FREEPORT
State
PA
ZIP
16229
Mailing
344 SECOND STREET, FREEPORT, PA 16229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423990
Employees
4
Ownership type
A

5 citations on file for this inspection.

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 3, 2024
Abate by
Sep 23, 2024
Penalty
Initial $3,457 · Current $3,457

Hazardous substances 9000S103

29 CFR  1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Worksite; 344 Second St. Freeport, PA, on or about March 6, 2024 - The employer did not maintain a written hazard communication program.  Employees were exposed to hazardous solvents such as, but not limited to, Lithichrome aerosol/Black Shadow (which contained acetone, ethyl acetate, MIK, N-Butane and xylene), stencil filler (which contained toluene and heptane), and granite headstones (which contained quartz silica) while fabricating pre-ordered monument related products.
Recent events (1)
  • — Z (S) $3457

1910.1200 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 3, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 9000S103

29 CFR  1910.1200(g)(1):  Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  (a) Worksite; 344 Second St. Freeport, PA, on or about March 6, 2024 - The employer did not maintain safety data sheets for hazardous solvents such as, but not limited to, Lithichrome aerosol/Black Shadow (which contained acetone, ethyl acetate, MIK, N-Butane and xylene), stencil filler (which contained toluene and heptane), and granite headstones (which contained quartz silica) while fabricating pre-ordered monument related products.
Recent events (1)
  • — Z (S) $0

1910.1200 F06

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 3, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 9000S103

29 CFR  1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  (a) Worksite; 344 Second St. Freeport, PA, on or about April 30, 2024 - A small in-house container of stencil filler which contained toluene and heptane was not labeled with the contents or the hazardous warning of the solvent.
Recent events (1)
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 3 exposed
Issued
Sep 3, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:   (a) Worksite; 344 Second St. Freeport, PA, on or about April 30, 2024 - The employer allowed for voluntary respiratory usage of tightfitting N95 particulate respirator and 1/2 face air purifying respirator while manufacturing quartz containing headstones.  Employees were not provided Appendix D of the respirator standard.
Recent events (1)
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 3, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  (a) Worksite; 344 Second St. Freeport, PA, on or about March 6, 2024 - The employer allowed for voluntary respiratory usage but did not maintain a written respiratory protection program to provide employees information on selection, storage, cleaning and fit tests. Employees were offered 1/2 face air purifying respirator and N95 particulate respirator while either outside sandblasting booth or inside  inside the sandblasting booth applying organic solvents.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347376386.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.