Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BLUETRITON BRANDS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BLUETRITON BRANDS, INC. in 4718 MOUNTAIN CREEK PARKWAY, DALLAS, TX 75236 (NAICS 312112). OSHA activity number 347378994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bluetriton Brands, INC. — free Get an email when a new federal OSHA severe-injury report for Bluetriton Brands, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4718 MOUNTAIN CREEK PARKWAY
City
DALLAS
State
TX
ZIP
75236
Mailing
4718 MOUNTAIN CREEK PARKWAY, DALLAS, TX 75236
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312112
Employees
220
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2024
Abate by
Aug 22, 2024
Penalty
Initial $11,524 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  (a) On or before March 28, 2024, in the plant employees performing maintenance to the Douglas tray packer on line 8 were not protected in that the procedures did not clearly and specifically outline the scope, authorization, rules, and techniques to be utilized for the control of hazardous energy and the means to enforce compliance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.147 C06 I

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Jul 29, 2024
Abate by
Aug 22, 2024
Penalty
Initial $11,524 · Current $6,915 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) On or before March 28, 2024, employees were not protected from hazards related to the unexpected energization, startup, or release of stored energy while performing maintenance on the Douglas tray packer on line 8 in that a periodic inspection of the procedures used was not done.
Recent events (2)
  • — I (O) $6915
  • — Z (S) $11524

View Bluetriton Brands, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347378994.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.