BELTON, TX —
OSHA Inspection: C F SUPPLY INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of C F SUPPLY INC. in 7180 U.S. 190 FRONTAGE ROAD, BELTON, TX 76513 (NAICS 444190). OSHA activity number 347379034.
Where did this inspection happen?
- Establishment
- C F SUPPLY INC.
- Site address
- 7180 U.S. 190 FRONTAGE ROAD
- City
- BELTON
- State
- TX
- ZIP
- 76513
- Mailing
- 7180 U.S. HWY 190 FRONTAGE ROAD, BELTON, TX 76513
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.110 F06 II
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
2150
General-duty citation text
29 CFR 1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering. On or about March 28, 2024, and at times prior thereto, employees were exposed to a combustible hazard when propane cylinders used for forklift operations were stored within a propane cage that was not locked, subject to tampering by unauthorized persons.
Recent events (2)
- — I (O) $1382.5
- — Z (S) $2765
1910.178 L06
- Issued
- Abate by
- Penalty
- Initial $3687.00 · Current $1844.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): On or about March 28, 2024, and at times prior thereto, employees were exposed to a struck-by hazard from the forklift or the load when employees operating the forklifts had not been trained and evaluated.
Recent events (2)
- — I (S) $1843.5
- — Z (S) $3687
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $3687.00 · Current $1844.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about March 28, 2024, and at times prior thereto, employees were exposed to a chemical hazard when the employer did not develop a hazard communication program to include employees stirring hazardous chemical products such as, but not limited to, Senergy Senerflex - Maxi White finishing material.
Recent events (2)
- — I (S) $1843.5
- — Z (S) $3687
More inspections in this industry (NAICS 444190)
SALT LAKE CITY, UT—2026-07-15
FOR-SHOR CO
HARWICH, MA—2026-07-07
NORTHEAST PINE COMPANIES, INC.
HARRISBURG, PA—2026-07-02
SECURITY FENCE COMPANY
BEND, OR—2026-06-30
317744596 - NELSON TILE & STONE INC
VARNA, IL—2026-06-26
ANTHEM BUILT, LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347379034.