Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R & G CONSTRUCTION GROUP INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of R & G CONSTRUCTION GROUP INC in 409 WARBURTON AVE, YONKERS, NY 10701 (NAICS 238130). OSHA activity number 347392029.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R & G Construction Group INC — free Get an email when a new federal OSHA severe-injury report for R & G Construction Group INC is published. One employer, no account, unsubscribe in one click.
Site address
409 WARBURTON AVE
City
YONKERS
State
NY
ZIP
10701
Mailing
184 HELENA AVE, YONKERS, NY 10710
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 24, 2024
Penalty
Initial $4,148 · Current $2,170 Reduced
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Workers did not have hard hats on site were exposed to head impact.
Recent events (2)
  • — I (S) $2170
  • — Z (S) $4148

1926.501 B02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2024
Penalty
Initial $4,839 · Current $2,540 Reduced
29 CFR  1926.501(b)(2)(i):Each employee who was constructing a leading edge 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Employee without fall protection was exposed to a fall of  approx. 20 ft to the ground while working on the 3rd floor metal deck.
Recent events (2)
  • — I (S) $2540
  • — Z (S) $4839

1926.502 I03

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 24, 2024
Penalty
Initial $4,839 · Current $2,540 Reduced
29 CFR  1926.502(i)(3):All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Employees were exposed to a fall of approx. 8 ft to the lower level while working next to a 3ft by 6ft floor opening that was partially covered with unsecured wood beams.
Recent events (2)
  • — I (S) $2540
  • — Z (S) $4839

1926.502 I04

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 24, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.502(i)(4):All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Cover for the floor opening was not color coded or marked with the words hole or cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2024
Penalty
Initial $4,839 · Current $2,540 Reduced
29 CFR  1926.1053(b)(13):The top or top step of a stepladder was used as a step:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Employee was exposed to a fall by standing at the top of a stepladder while installing joist hungers.
Recent events (2)
  • — I (S) $2540
  • — Z (S) $4839

1926.150 A03

Other-than-serious 1 instance 5 exposed
Issued
Apr 24, 2024
Penalty
Initial $388 · Current $210 Reduced
29 CFR  1926.150(a)(3):Firefighting equipment, provided by the employer, was not conspicuously located:  On or about March 15th, 2024 Location: 409 Warburton Ave, Yonkers, NY 10701  a) Fire extinguishers were not conspicuously located through out the site.
Recent events (2)
  • — I (O) $210
  • — Z (O) $388

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347392029.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.