SANDWICH, IL —
OSHA Inspection: FABTEK AERO LTD.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FABTEK AERO LTD. in 775 DUVICK AVENUE, SANDWICH, IL 60548 (NAICS 332420). OSHA activity number 347395550.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FABTEK AERO LTD.
- Site address
- 775 DUVICK AVENUE
- City
- SANDWICH
- State
- IL
- ZIP
- 60548
- Mailing
- 775 DUVICK AVENUE, SANDWICH, IL 60548
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 28
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 6, 2024
- Abate by
- Sep 23, 2024
- Penalty
- Initial $6,453 · Current $4,517 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about April 3, 2024, the employer did not ensure that energy control procedures were documented and utilized to control hazardous energy (electrical) to prevent unexpected start-up of the plasma cutting system when employees were engaged in servicing and maintenance activities, exposing employees to crushing hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $4517.1
- — Z (S) $6453
1910.305 B02 I
- Issued
- Sep 6, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i):All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. On or about April 3, 2024, the employer did not ensure that junction boxes located in the back area of workshop were provided with covers.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Fabtek Aero LTD.