Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOLD GLASS GROUP CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GOLD GLASS GROUP CORP. in 545-5 JOHNSON AVENUE, BOHEMIA, NY 11716 (NAICS 541614). OSHA activity number 347396277.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gold Glass Group Corp. — free Get an email when a new federal OSHA severe-injury report for Gold Glass Group Corp. is published. One employer, no account, unsubscribe in one click.
Site address
545-5 JOHNSON AVENUE
City
BOHEMIA
State
NY
ZIP
11716
Mailing
545-4 JOHNSON AVENUE, BOHEMIA, NY 11716
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541614
Employees
20
Ownership type
A

6 citations on file for this inspection.

1910.157 C01

Other-than-serious Gravity 1 1 instance 35 exposed
Issued
May 23, 2024
Abate by
Jun 5, 2024
Penalty
Initial $4,839 · Current $3,500 Reduced
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located, and identified so that they were readily accessible without subjecting the employees to injuries:  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - A Fire Extinguisher was blocked and not readily accessible: on or about 4/5/24.   Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $4839

1910.157 E01

Other-than-serious Gravity 1 1 instance 35 exposed
Issued
May 23, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - A Fire Extinguisher was missing: on or about 4/5/24.   Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 G02

Other-than-serious Gravity 1 1 instance 35 exposed
Issued
May 23, 2024
Abate by
Jun 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - The employer did not educate employees on fire extinguishers: on or about 4/5/24.   Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 35 exposed
Issued
May 23, 2024
Abate by
Jun 3, 2024
Penalty
Initial $4,839 · Current $3,500 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - Multiple power strips were used as a substitute for fixed wiring to power Impulse Poly Bag Sealers: on or about 4/5/24.   Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4839

1910.305 G01 IV A

Serious Gravity 1 1 instance 35 exposed
Issued
May 23, 2024
Abate by
Jun 5, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - Multiple power strips were used as a substitute for fixed wiring to power Impulse Poly Bag Sealers: on or about 4/5/24.   Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 35 exposed
Issued
May 23, 2024
Abate by
Jun 5, 2024
Penalty
Initial $1,613 · Current $500 Reduced
29 CFR  1904.40(a):The employer did not provide an authorized government representative the records within the four business hours.  a) Worksite: 545-4 Johnson Avenue, Bohemia, NY 11716 - The employer did not provide the requested OSHA logs: on or about 4/5/24.   Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (O) $500
  • — Z (O) $1613

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347396277.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.