OSHA Inspection: STOLBERGER INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of STOLBERGER INCORPORATED in 1211 HIGH STREET, CENTRAL FALLS, RI 02863 (NAICS 332710). OSHA activity number 347402570.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stolberger Incorporated — free Get an email when a new federal OSHA severe-injury report for Stolberger Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1211 HIGH STREET
City
CENTRAL FALLS
State
RI
ZIP
02863
Mailing
1211 HIGH STREET, CENTRAL FALLS, RI 02863
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
332710
Employees
48
Ownership type
A

14 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $11,292 · Current $5,646 Reduced
29 CFR 1910.107(b)(5)(i): The spraying operations (except electrostatic spraying operations) were not designed, installed and maintained such that the average air velocity over the open face of the booth (or booth cross section during spraying operations) was not less than 100 linear feet per minute. Visible gauges or audible alarm or pressure activated devices were not installed to indicate or ensure that the required air velocity was maintained. Filter rolls were not inspected to insure proper replacement of filter media.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the cross-section air velocity of the paint booth was measured and calculated to be 27.3 linear feet per minute, exposing employees to a flammable vapor hazard while spray painting in the booth with paints including, but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303,  with a Flash Point of Closed cup: 2°C (35.6°F) Highly flammable liquid and vapor.
Recent events (2)
  • — I (S) $5646
  • — Z (S) $11292

1910.107 B09

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not ensure that a clear space of 3 feet or more on all sides was kept free from storage or combustible construction to allow access for cleaning. Combustible wood blocks, plywood, and cardboard were leaning against the right side of the paint booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C08

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.107(c)(8): Portable electric lamps shall not be used in any spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, shall be of the type approved for hazardous Class I locations.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, a portable electric lamp, not approved for hazardous locations, was used in the spraying area during spraying operations where highly flammable liquids and vapors were used including, but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303, with a Flash Point of Closed cup: 2°C (35.6°F).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.107(f)(3): Sprinklers protecting spraying areas were not kept as free from deposits as practical by cleaning daily if necessary.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not ensure that sprinklers protecting spraying areas were kept as free from deposits as practical and interfered with the operation of the sprinkler by covering the sprinkler with a disposable glove.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not keep the walls, ceiling and floor of the paint booth free from the accumulation of deposits of combustible residues and thereby exposing employees to fire and explosion hazards while spray painting in the booth with paints including, but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303, with a Flash Point of Closed cup: 2°C (35.6°F) Highly flammable liquid and vapor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $6,453 · Current $3,227 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for employees required to wear a respirator for tasks including but not limited to spray painting.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not establish and implement a workplace specific written respiratory protection program for employees required to wear respirators for tasks including but not limited to spray painting thereby exposing employee to respiratory hazards.
Recent events (2)
  • — I (S) $3226.5
  • — Z (S) $6453

1910.134 D01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not identify and evaluate the respiratory hazard(s) in the workplace for employees performing tasks including, but not limited to, spray painting thereby exposing employees to inhalation and respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator for employees required to wear respirators for tasks including, but not limited to spray painting, thereby exposing employees to respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) for employees performing tasks, including but not limited to, spray painting thereby exposing employees to inhalation and respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable respiratory protection training which did not occur annually and/or more often if necessary.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not provide comprehensive, understandable respiratory protection training for employees required to wear respirators while performing tasks, including but not limited to, spray painting, thereby exposing employees to inhalation and respiratory hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $8,067 · Current $4,034 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not fully implement and/or maintain at the workplace a written hazard communication program in that labeling was not adequate, SDSs were not current and training was not adequate, for employees working with hazardous chemicals including but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303, with a Flash Point of Closed cup: 2°C (35.6°F) which is highly flammable liquid and vapor.
Recent events (2)
  • — I (S) $4033.5
  • — Z (S) $8067

1910.1200 F06 II

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not ensure secondary containers containing various chemicals throughout the facility were marked appropriately to comply with the hazard communication standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not maintain copies of the required, current safety data sheets for each hazardous chemical, including but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303 which is highly flammable liquid and vapor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 25 exposed
Issued
Sep 16, 2024
Abate by
Oct 31, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.  Facility at 1211 High Street in Central Falls:  a. On or about 4/10/2024, the employer did not ensure employees received effective information and training on hazardous chemicals used in their work area, including but not limited to, Sherwin-Williams Quick Dry Enamel Blue F77XXL26645-4303, with a Flash Point of Closed cup: 2°C (35.6°F) which is highly flammable liquid and vapor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Stolberger Incorporated's full OSHA safety record →