Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MYERS CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MYERS CONSTRUCTION, LLC in 1663 MILL POND LANE, NEENAH, WI 54956 (NAICS 238130). OSHA activity number 347404584.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Myers Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Myers Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1663 MILL POND LANE
City
NEENAH
State
WI
ZIP
54956
Mailing
6755 SPIELEBERG ROAD, FREMONT, WI 54940
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 8, 2024
Penalty
Initial $2,351 · Current $1,176 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On or about April 10, 2024, with regard to a jobsite located at 1661 Mill Pond Road, Fox Crossing, WI 54956, employees of Myers Construction, LLC were exposed to fall hazards of greater than eight feet while performing truss setting operations on a new residential construction without the use of conventional fall protection.
Recent events (2)
  • — I (S) $1175.5
  • — Z (S) $2351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347404584.