On , OSHA opened a referral safety inspection of MCCARTHY MASONRY & CONCRETE INC. in 4701 PINE ST, PHILADELPHIA, PA 19143 (NAICS 238110). OSHA activity number 347408429.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCCARTHY MASONRY & CONCRETE INC.
- Site address
- 4701 PINE ST
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19143
- Mailing
- 740 EAST CHERRY ROAD, QUAKERTOWN, PA 18951
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 E01
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $9,680 · Current $6,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Scaffold frame was used as a means of access: a) 4701 Pine St, Philadelphia, PA 19143 - Exterior Scaffold, West side of building - On or about April 11, 2024, the employer did not ensure employees were provided safe means to access and egress the scaffold. Employees utilized the scaffold supports to access the 2nd level of the scaffold platform, thereby exposing employees to fall hazards of approximately 13.5 feet. b) 4701 Pine St, Philadelphia, PA 19143 - Exterior Scaffold, South side of building - On or about April 11, 2024, the employer did not ensure employees were provided safe means to access and egress the scaffold. Employees utilized the scaffold supports to access the 1st level of the scaffold platform, thereby exposing employees to fall hazards of approximately 6 feet.
Recent events (3)
- — F (O) $6000
- — C (S) $9680
- — Z (S) $9680
1926.451 F03
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $9,680 · Current $6,000 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) 4701 Pine St, Philadelphia, PA 19143 - On or about April 11, 2024, the employer did not inspect the scaffold and scaffold components for visible defects by a competent person before each shift. Employees worked on uninspected scaffolding performing masonry work, thereby exposing employees to fall hazards of approximately 6 feet to 13.5 feet.
Recent events (3)
- — F (O) $6000
- — C (S) $9680
- — Z (S) $9680
1926.451 G01
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $11,292 · Current $8,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) 4701 Pine St, Philadelphia, PA 19143 - On or about April 11, 2024, the employer did not ensure each employee working on a scaffold 10 feet above a lower level were protected from fall hazards. An employee was required to perform masonry facade work from a scaffold platform without guardrails or other means of fall protection, thereby exposing the employee to falls approximately 13.5 feet from the ground.
Recent events (3)
- — F (O) $8000
- — C (S) $11292
- — Z (S) $11292
1926.451 B01
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) 4701 Pine St, Philadelphia, PA 19143 - On or about April 11, 2024, the employer did not ensure each platform on all working levels of scaffolds was fully planked or decked between the front uprights and the guardrail supports. Employee performed masonry facade work on the front (southern side) of the building from a scaffold platform that was not fully planked, thereby exposing employees to fall hazards of approximately 6 feet. b) 4701 Pine St, Philadelphia, PA 19143 - On or about April 11, 2024, the employer did not ensure each platform on all working levels of scaffolds was fully planked or decked between the front uprights and the guardrail supports. Employee performed masonry facade work on the west side of the building from a scaffold platform that was not fully planked, which lacked three planks, thereby exposing employees to fall hazards of approximately 13.5 feet.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.451 E05 I
- Issued
- Oct 4, 2024
- Abate by
- Oct 24, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: a) 4701 Pine St, Philadelphia, PA 19143 - On or about April 11, 2024, the employer did not ensure ramps and walkways 6 feet or more above lower levels had adequate guardrail systems. Employees used a walkway made of scaffolding planks which connected two scaffolds located around the southwest corner of a building to access work areas to perform masonry facade work approximately 13.5 feet from the ground. The walkway lacked adequate guardrails, thereby exposing employees to fall hazards of approximately 13.5 feet.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at Mccarthy Masonry & Concrete INC.
View Mccarthy Masonry & Concrete INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347408429.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.