Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROYALTY ROOFING USA, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROYALTY ROOFING USA, LLC. in 9869 LAKE DISTRICT LAN, ORLANDO, FL 32832 (NAICS 238160). OSHA activity number 347409203.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Royalty Roofing USA, LLC. — free Get an email when a new federal OSHA severe-injury report for Royalty Roofing USA, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
9869 LAKE DISTRICT LAN
City
ORLANDO
State
FL
ZIP
32832
Mailing
2099 E. TIPTON ST., SEYMOUR, IN 47274
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 3, 2024
Penalty
Initial $8,067 · Current $4,034 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level.  a. On or about April 10, 2024, at the site, the employer did not ensure that the personal fall arrest system was rigged so as to not allow the employee to contact any lower level, exposing employees to a 25 feet fall hazard.
Recent events (2)
  • — I (S) $4033.5
  • — Z (S) $8067

1926.502 D21

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 3, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service.  a. On or about April 10, 2024, at the site, the employer did not ensure that the personal fall arrest system was inspected prior to each use, exposing employees to a 25-foot fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0