NORTHBROOK, IL —
OSHA Inspection: EDILBERTO LOPEZ DBA TOTAL PLUS ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDILBERTO LOPEZ DBA TOTAL PLUS ROOFING in 2410 WHITE OAK DRIVE, NORTHBROOK, IL 60062 (NAICS 238160). OSHA activity number 347417230.
Where did this inspection happen?
- Establishment
- EDILBERTO LOPEZ DBA TOTAL PLUS ROOFING
- Site address
- 2410 WHITE OAK DRIVE
- City
- NORTHBROOK
- State
- IL
- ZIP
- 60062
- Mailing
- 1921 WALLACE AVE., NORTH CHICAGO, IL 60064
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 D01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials: a) On April 16, 2024, the connection of personal fall arrest equipment used by employees working from pitched roofs consisted of synthetic ropes that had been knotted/tied to the dee-ring of hinged roof anchors. No abatement certification or documentation required for this violation.
Recent events (1)
- — Z (O) $0
1926.502 D15
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) On or about April 16, 2024, roof anchors used as part of fall protection systems were not connected completely to the roof deck to ensure the device would be capable of supporting at least 5,000 pounds of force. No abatement certification or documentation required for this violation.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source