EAST AURORA, NY —
OSHA Inspection: ADVANCED NOZZLE TECHNOLOGY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED NOZZLE TECHNOLOGY LLC in 12928 BIG TREE, EAST AURORA, NY 14052 (NAICS 332710). OSHA activity number 347417883.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED NOZZLE TECHNOLOGY LLC
- Site address
- 12928 BIG TREE
- City
- EAST AURORA
- State
- NY
- ZIP
- 14052
- Mailing
- 12928 BIG TREE, EAST AURORA, NY 14052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 14
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.242 B
- Issued
- May 16, 2024
- Abate by
- Jun 10, 2024
- Penalty
- Initial $2,074 · Current $1,556 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 04/17/2024, in the CNC area, employees are exposed to flying debris when using airlines for cleaning parts with compressed air pressures of about 68 p.s.i without a regulated nozzle. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1555.5
- — Z (S) $2074
1910.305 G01 IV A
- Issued
- May 16, 2024
- Abate by
- Jun 10, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 4/17/2023 in the CNC Area; where an extension cord was used in place of fixed wiring to power a lamp. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347417883.