ENGLEWOOD, NJ —
OSHA Inspection: ARCO/MURRAY NATIONAL DALLAS, INC.
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of ARCO/MURRAY NATIONAL DALLAS, INC. in 150 S DEAN ST, ENGLEWOOD, NJ 07631 (NAICS 236220). OSHA activity number 347422073.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCO/MURRAY NATIONAL DALLAS, INC.
- Site address
- 150 S DEAN ST
- City
- ENGLEWOOD
- State
- NJ
- ZIP
- 07631
- Mailing
- 3110 WOODCREEK DR, DOWNERS GROVE, IL 60515
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 400
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 F06
- Issued
- Sep 5, 2024
- Penalty
- Initial $16,131 · Current $16,131
General-duty citation text
29 CFR 1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). a) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing aluminum flashing from an articulated boom basket that was approximately betweeen 97 inches and 113 inches from a 69KV energized primary line, on or about 3/25/24 b) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing siding from an articulated boom basket that was approximately between 97 inches and 113 inches from a 69KV energized primary line, on or about 3/11/24
Recent events (2)
- — I (O) $16131
- — Z (S) $16131
1926.416 A01
- Issued
- Sep 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work: (a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) a) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing 10 feet long aluminum flashing pieces from an articulated boom basket that was approximately betweeen 97 inches and 113 inches from a 69KV, on or about 3/25/24 b) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing 10 feet long siding elements from an articulated boom basket that was approximately betweeen 97 inches and 113 inches from a 69KV energized primary line, on or about 3/11/24
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.416 A03
- Issued
- Sep 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): The employer began work without determining if employees could contact any part of an energized circuit and did not post warning signs and advise employees of the location of the circuit, hazards, and protective measures they need to take. a) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing aluminum flashing from an articulated boom basket that was approximately betweeen 97 inches and 113 inches from a 69KV energized primary line without any warning signs and or advise of protective measures they needed to take, on or about 3/25/24 b) At or near 150 S Dean St, Englewood NJ - Articulated Boom Basket: workers were exposed to electric hazards while installing siding from an articulated boom basket that was approximately betweeen 97 inches and 113 inches from a 69KV energized primary line without any warning signs and or advise of protective measures they needed to take , on or about 3/11/24
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Arco/Murray National Dallas, INC.
View Arco/Murray National Dallas, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347422073.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.