MENTOR, OH —
OSHA Inspection: VICON FABRICATING CO., LTD
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VICON FABRICATING CO., LTD in 7200 JUSTIN WAY, MENTOR, OH 44060 (NAICS 332312). OSHA activity number 347428062.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VICON FABRICATING CO., LTD
- Site address
- 7200 JUSTIN WAY
- City
- MENTOR
- State
- OH
- ZIP
- 44060
- Mailing
- 7200 JUSTIN WAY, MENTOR, OH 44060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 49
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 17, 2024
- Penalty
- Initial $9,680 · Current $5,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. On or about April 30, 2024, the employer failed to ensure employees were protected from struck-by hazards from potentially falling loads while operating overhead cranes equipped with below-the-hook lifting devices, such as manually operated lifting magnets and steel plate lifting shoes, without the rated load of the lifting devices labelled and/or legibly marked. According to ASME B30.20-2021; Below-the-Hook Lifting Devices, Safety Standard for Cableways, Cranes, Derricks, Hoists, Hooks, Jacks, and Slings; Chapter 20-1 Structural and mechanical Lifting Devices. SECTION 20-1.2.1 MARKING. (a) Rated Load. The rated load of the lifting device shall be legibly marked on its main structure or on a tag attached to its main structure where it is visible. If the lifting device is made up of several lifters, each detachable from the group, these lifters shall also be marked with their individual rated loads. Chapter 20.3 Close Proximity Operated Lifting Magnets; SECTION 20-3.2: MARKING, CONSTRUCTION, AND INSTALLATION, 20-3.2.1 Marking, (a) Rated Load, (1) General Application Lifting Magnets. The rated load of the lifting magnet shall be legibly marked on the lifting magnet or on a tag attached to the lifting magnet where it is visible. This marking shall refer to the instruction manual for information relating to decreases in rating due to the load surface condition, thickness, percentage of contact with the lifting magnet, temperature, metallurgical composition, and deflection.
Recent events (2)
- — I (S) $5000
- — Z (S) $9680
1910.184 C01
- Issued
- Jun 17, 2024
- Penalty
- Initial $6,453 · Current $2,900 Reduced
General-duty citation text
29 CFR 1910.184(c)(1):Slings that are damaged or defective shall not be used. On or about April 30, 2024, the employer failed to ensure a damaged and/or defective double-leg chain sling, Serial No. 41890A, was not used by employees to lift loads with the 10-ton crane located near the Cincinnati Press Brake Machine.
Recent events (2)
- — I (S) $2900
- — Z (S) $6453
1910.184 C04
- Issued
- Jun 17, 2024
- Abate by
- Aug 5, 2024
- Penalty
- Initial $9,680 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.184(c)(4):Slings shall not be loaded in excess of their rated capacities. On or about April 29, 2024, the employer failed to ensure employees did not load chain slings in excess of their rated capacity.
Recent events (2)
- — I (S) $5000
- — Z (S) $9680
1910.37 A03
- Issued
- Jun 17, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3):Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. a. On or about April 30, 2024, the employer failed to ensure an exit route located near the rear loading dock, South side of building, was free and unobstructed. A flexible power cable and rubber drain lines were located on the floor in front of the exit door creating trip hazards and obstructing it's use. b. On or about April 30, 2024, the employer failed to ensure an exit route located on the East side of the building, near the overhead door was free and unobstructed. An air hose was running across the floor in front of the exit door creating trip hazards and obstructing it's use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347428062.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.