Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARCIA ALCAUTER CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GARCIA ALCAUTER CONSTRUCTION LLC in 201 WYMAN LAKE DRIVE, DELAWARE, OH 43015 (NAICS 238130). OSHA activity number 347434524.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garcia Alcauter Construction LLC — free Get an email when a new federal OSHA severe-injury report for Garcia Alcauter Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
201 WYMAN LAKE DRIVE
City
DELAWARE
State
OH
ZIP
43015
Mailing
2283 EDEN AVE., COLUMBUS, OH 43224
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 30, 2024
Abate by
Jun 11, 2024
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.502(d)(16): Personal fall arrest systems, when stopping a fall, shall:  29 CFR 1926.502(d)(16)(iii): be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;  a. Located at the job site at 201 Wyman Lake Drive, Delaware, Ohio 43015: On or about April 24, 2024, the employer did not ensure that the personal fall arrest system components, such as the full body harnesses, were properly rigged in that the harness did not fit and was too loose, therefore allowing the employee to contact the lower level. As a result, an employee was exposed to a fall hazard of approximately 18 feet.
Recent events (2)
  • — I (S) $3803
  • — Z (S) $3803

1926.502 D17

Serious Gravity 5 1 instance 1 exposed
Issued
May 30, 2024
Abate by
Jun 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.  a. Located at the job site at 201 Wyman Lake Drive, Delaware, Ohio 43015: On or about April 24, 2024, the employer did not ensure that the full body harness fit properly in that it was too loose, resulting in the attachment point not being in the center of the wearer's back near shoulder level. As a result, employees were exposed to serious injuries in the event of a fall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C12

Serious Gravity 5 1 instance 5 exposed
Issued
May 30, 2024
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.  a. Located at the job site at 201 Wyman Lake Drive, Delaware, Ohio 43015: On or about April 24, 2024, the employer did not ensure that the unprotected sides of the stairway landing that employees utilized to access the second story to perform framing work had guardrails in place. As a result, employees were exposed to a fall hazard of approximately 14 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
May 30, 2024
Abate by
Jun 11, 2024
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. Located at the job site at 201 Wyman Lake Drive, Delaware, Ohio 43015: On or about April 24, 2024, the employer did not ensure that the portable ladder utilized for accessing the roof was extended at least 3 feet beyond the surface being accessed and/or secured at its top to a rigid support and that a grasping device was utilized. As a result, employees were exposed to a fall hazard of approximately 18 feet to the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

View Garcia Alcauter Construction LLC's full OSHA safety record →