PALMERTON, PA —
OSHA Inspection: AMPAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMPAL, INC. in 2115 LITTLE GAP ROAD, PALMERTON, PA 18071 (NAICS 331314). OSHA activity number 347440547.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMPAL, INC.
- Site address
- 2115 LITTLE GAP ROAD
- City
- PALMERTON
- State
- PA
- ZIP
- 18071
- Mailing
- 2115 LITTLE GAP ROAD, PALMERTON, PA 18071
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331314
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 C01
- Issued
- Sep 26, 2024
- Abate by
- Oct 30, 2024
- Penalty
- Initial $906 · Current $906
General-duty citation text
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) Production Areas - On or about August 21, 2024, the employer did not provide a written certification to OSHA that the abatement was complete.
Recent events (1)
- — Z (O) $906
1910.95 C01
- Issued
- Jul 19, 2024
- Abate by
- Aug 21, 2024
- Penalty
- Initial $11,292 · Current $11,292
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) Production Areas - On or about May 14, 2024, the employer did not administer a continuing, effective hearing conservation program when employees were exposed in the P1 and P2 furnace buildings to occupational noise for an 8-hour time weighted average of 92.5 dBA. Zero exposure is assumed for the eighty-eight minutes not sampled. (b) Production Areas - On or about May 14, 2024, the employer did not administer a continuing, effective hearing conservation program when employees were exposed in the P1 and P2 furnace buildings to occupational noise for an 8-hour time weighted average of 91.9 dBA. Zero exposure is assumed for the ninety-five minutes not sampled. Abatement Certification and Documentation Required.
Recent events (1)
- — Z (S) $11292
1910.147 C04 I
- Issued
- Jul 19, 2024
- Penalty
- Initial $8,067 · Current $8,067
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Receivers - On or about April 25, 2024, employees required to clean aluminum scale off the interior walls of receiver vessels were exposed to thermal energy and struck-by hazards because the vessels were not locked out prior to entry. Certification Not Required.
Recent events (1)
- — Z (S) $8067
1910.215 B09
- Issued
- Jul 19, 2024
- Penalty
- Initial $8,067 · Current $8,067
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) P1 Furnace Building - On or about April 25, 2024, employees operating the bench grinder were exposed to struck-by hazards because the bench grinder was not equipped with an adjustable tongue guard. Certification Not Required.
Recent events (1)
- — Z (S) $8067
1904.29 B01
- Issued
- Jul 19, 2024
- Abate by
- Jul 31, 2024
- Penalty
- Initial $1,613 · Current $1,613
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation: (a) Site Wide - On or about April 2, 2024, the employer did not provide a description of the injury or illness suffered by the employee, in column F for each employee listed on the 300 logs. Certification Not Required.
Recent events (1)
- — Z (O) $1613
1910.147 C06 II
- Issued
- Jul 19, 2024
- Abate by
- Sep 5, 2024
- Penalty
- Initial $906 · Current $906
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Production Areas - On or about April 25, 2024, the employer failed to verify via a written certification, that the energy control procedures had been inspected at least annually. Abatement Certification Required.
Recent events (2)
- — Z $9060
- — Z (O) $906
More inspections at Ampal, INC.
View Ampal, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331314)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347440547.