SHARON, PA —
OSHA Inspection: M & G ROOFING & SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M & G ROOFING & SIDING in 853 HIGHLAND ROAD, SHARON, PA 16146 (NAICS 238160). OSHA activity number 347446346.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & G ROOFING & SIDING
- Site address
- 853 HIGHLAND ROAD
- City
- SHARON
- State
- PA
- ZIP
- 16146
- Mailing
- 3619 IRMA STREET, YOUNGSTOWN, OH 44502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Jun 12, 2024
- Abate by
- Jul 10, 2024
- Penalty
- Initial $5,323 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) M & G Roofing & Siding; 853 Highland Road, Sharon, PA 16146: Residential roof- on or about 04/29/2024 and at times prior thereto, employees were conducting roofing operations on a residential roof with a 6:12 pitch without any fall protection systems. Employees were exposed to fall hazard of 10-feet above ground level.
Recent events (2)
- — I (S) $3000
- — Z (S) $5323
1926.502 D21
- Issued
- Jun 12, 2024
- Abate by
- Jul 10, 2024
- Penalty
- Initial $5,323 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a.) M & G Roofing & Siding; 853 Highland Road, Sharon, PA 16146: Residential roof- on or about 04/29/2024 and at times prior thereto, employees were installing shingles and performing tear off operations on a roof with a 6:12 pitch. Employees were observed using climbing harnesses as a means of fall protection and were exposed to a fall arrest condition with a 10-foot fall hazard. The climbing harnesses used by employees did not attach to the wearers back.
Recent events (2)
- — I (S) $2000
- — Z (S) $5323
1926.503 A02
- Issued
- Jun 12, 2024
- Abate by
- Jul 10, 2024
- Penalty
- Initial $4,563 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.503(a)(2):The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii). a.) M & G Roofing & Siding; 853 Highland Road, Sharon, PA 16146: Residential roof- on or about 04/29/2024 and at times prior thereto, employer did not provide training to employees that were performing roof work operations on a residential roof. Employees were exposed to fall hazards of 10-feet above ground level. Employees did not have fall protection training.
Recent events (2)
- — I (S) $2000
- — Z (S) $4563
1926.1053 B01
- Issued
- Jun 12, 2024
- Penalty
- Initial $2,586 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a.) M & G Roofing & Siding; 853 Highland Road, Sharon, PA 16146: Residential roof- on or about 04/29/2024 and at times prior thereto, the Davidson extension ladder that was utilized to access the roof was only 2-feet above the roof line 24-feet above ground level.
Recent events (2)
- — I (S) $2000
- — Z (S) $2586
More inspections at M & G Roofing & Siding
View M & G Roofing & Siding's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347446346.