OSHA Inspection: SYMMETRY MEDICAL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SYMMETRY MEDICAL, INC. in 253 ABBY RD., MANCHESTER, NH 03101 (NAICS 332112). OSHA activity number 347450355.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Symmetry Medical, INC. — free Get an email when a new federal OSHA severe-injury report for Symmetry Medical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
253 ABBY RD.
City
MANCHESTER
State
NH
ZIP
03101
Mailing
253 ABBY RD., MANCHESTER, NH 03101
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332112
Employees
133
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 3, 2024
Abate by
Aug 20, 2024
Penalty
Initial $11,524 · Current $8,067 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Location: site - On or about 3/1/2024, the employer had not conducted an inspection of the energy control procedures since 2020
Recent events (2)
  • — I (S) $8066.8
  • — Z (S) $11524

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 3, 2024
Penalty
Initial $6,913 · Current $4,839 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   Location: powder coat area - On or about 3/1/2024, the employer did not ensure drill presses had guards in place during operation to protect employees from rotating parts and flying chip hazards.
Recent events (2)
  • — I (S) $4839.1
  • — Z (S) $6913

1910.335 A01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 3, 2024
Abate by
Aug 20, 2024
Penalty
Initial $11,524 · Current $8,067 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:   Location: site - On or about 3/1/2024, employees were not protected from electrical shock and burns when testing electrical circuits without personal protective equipment.
Recent events (2)
  • — I (S) $8066.8
  • — Z (S) $11524

1910.147 C07 IV

Other-than-serious 1 instance 1 exposed
Issued
Jul 3, 2024
Abate by
Aug 20, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  Location: site - On or about 5/1/2024, the employer did not certify a maintenance technician performing lockout had been trained as an authorized person for lock out/ tag out.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0